Tecumseh AWF5532EXN Performance Data Sheet

Performance Data Sheet
AWF5532EXN
General Information
Model AWF5532EXN Refrigerant R-22 Test Condition ARI Performance Test Voltage 230V ~ 60HZ Return Gas 18.3°C (65°F) RETURN GAS Motor Type PSC
Performance Information
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 8200 6850 Watts 1300 1260 Amps 5.74 5.70
Lb/h 105 92.3
Btu/h 10300 8930 7670 Watts 1400 1370 1350 Amps 6.19 6.22 6.23
Lb/h 132 119 107
Btu/h 12600 11100 9760 8520 Watts 1490 1480 1480 1480 Amps 6.62 6.71 6.79 6.83
Lb/h 160 147 135 124
Btu/h 15000 13400 11900 10600 9330 Watts 1570 1580 1600 1630 1640 Amps 7.01 7.18 7.33 7.45 7.51
Lb/h 189 176 164 152 140
Btu/h 17500 15800 14300 12800 11400 Watts 1650 1680 1720 1760 1800 Amps 7.37 7.61 7.85 8.05 8.19
Lb/h 220 206 194 182 170
Btu/h 20200 18400 16700 15200 13700 12100 10500 Watts 1710 1760 1830 1890 1950 1990 2000 Amps 7.68 8.01 8.33 8.61 8.85 9.00 9.05
Lb/h 252 238 225 213 201 187 171
Btu/h 23100 21100 19300 17700 16000 14400 12600 Watts 1770 1840 1930 2020 2100 2160 2190 Amps 7.96 8.37 8.77 9.15 9.48 9.73 9.88
Lb/h 287 272 259 247 234 220 203
Btu/h 26200 24100 22200 20300 18600 16700 14900 Watts 1820 1910 2020 2130 2230 2320 2380 Amps 8.18 8.68 9.18 9.65 10.1 10.4 10.7
Lb/h 324 308 295 282 269 254 238
Btu/h 29600 27300 25200 23200 21300 19300 17300
25
30
35
40
45
50
55
Watts 1860 1970 2100 2240 2360 2480 2560 Amps 8.35 8.94 9.54 10.1 10.6 11.1 11.5
Lb/h 363 347 333 320 306 291 274
Btu/h 33300 30800 28500 26300 24200 22100 19900 Watts 1880 2020 2170 2330 2490 2620 2730 Amps 8.47 9.16 9.85 10.5 11.2 11.7 12.2
Lb/h 405 389 374 361 346 331 313
Btu/h 37200 34600 32100 29700 27400 25100 22700 Watts 1900 2060 2230 2420 2600 2760 2900 Amps 8.53 9.32 10.1 10.9 11.6 12.3 12.9
Lb/h 451 434 419 404 389 373 355
Btu/h 41500 38600 35900 33300 30800 28300 25700 Watts 1900 2080 2280 2490 2690 2890 3050 Amps 8.53 9.42 10.3 11.2 12.1 12.9 13.6
Lb/h 500 482 466 451 435 418 399
Btu/h 46200 43000 40100 37300 34500 31800 29000 Watts 1880 2090 2320 2550 2780 3000 3190 Amps 8.46 9.47 10.5 11.5 12.5 13.4 14.2
Lb/h 553 534 517 501 485 467 447
Btu/h 51200 47800 44600 41600 38600 35600 32600 Watts 1860 2090 2340 2600 2860 3100 3330 Amps 8.32 9.44 10.6 11.7 12.8 13.9 14.8
Lb/h 609 590 572 555 538 520 499
Btu/h 56600 52900 49500 46200 43000 39700 36400 Watts 1810 2070 2350 2630 2920 3190 3440 Amps 8.11 9.35 10.6 11.9 13.1 14.3 15.4
Lb/h 670 650 631 613 595 576 554
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 4.162348E+04 3.091660E+03 8.066740E+00 4.760486E+02 C2 6.730023E+02 -9.315870E+00 -2.008677E-02 6.487273E+00 C3 -5.663829E+02 -4.932017E+01 -6.879193E-02 -6.770032E+00 C4 5.470598E+00 -2.347083E-01 -1.384175E-03 4.163500E-02 C5 -2.517464E+00 2.498657E-01 9.214400E-04 -8.278155E-03 C6 3.788186E+00 5.161265E-01 1.016755E-03 5.326839E-02 C7 3.282196E-02 -1.088559E-03 -4.852386E-06 3.677334E-04 C8 -3.020108E-02 1.072573E-03 8.144992E-06 -1.406065E-04 C9 2.767899E-03 8.163826E-04 3.341388E-06 2.108862E-05
C10 -1.092190E-02 -1.717711E-03 -4.020774E-06 -1.681038E-04
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature
Loading...