Tecumseh AWF5528EXT Performance Data Sheet

Performance Data Sheet
AWF5528EXT
General Information
Model AWF5528EXT Refrigerant R-22 Test Condition ARI Performance Test Voltage 230V 3~ 60HZ Return Gas 18.3°C (65°F) RETURN GAS Motor Type 3PH
Performance Information
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 7050 6100 Watts 1130 1060 Amps 4.46 4.36
Lb/h 90.6 81.9
Btu/h 8850 7770 6720 Watts 1260 1220 1170 Amps 4.67 4.60 4.53
Lb/h 113 104 93.6
Btu/h 10800 9620 8420 7270 Watts 1380 1360 1330 1290 Amps 4.86 4.83 4.80 4.76
Lb/h 138 127 116 105
Btu/h 13000 11600 10300 9010 7750 Watts 1470 1480 1480 1470 1430 Amps 5.03 5.04 5.05 5.05 5.04
Lb/h 164 153 141 129 116
Btu/h 15300 13900 12400 10900 9510 Watts 1550 1580 1610 1620 1610 Amps 5.17 5.22 5.27 5.32 5.35
Lb/h 193 181 168 155 141
Btu/h 17900 16300 14600 13000 11500 9940 8480 Watts 1610 1670 1720 1750 1770 1770 1750 Amps 5.30 5.38 5.48 5.57 5.65 5.71 5.74
Lb/h 223 211 198 184 169 154 138
Btu/h 20600 18900 17100 15300 13600 11900 10300 Watts 1660 1740 1810 1870 1920 1940 1940 Amps 5.40 5.53 5.66 5.80 5.92 6.03 6.11
Lb/h 256 243 229 214 199 183 166
Btu/h 23600 21700 19700 17800 15900 14100 12300 Watts 1700 1800 1890 1980 2050 2100 2130 Amps 5.49 5.65 5.83 6.01 6.18 6.33 6.46
Lb/h 291 277 263 248 231 214 197
Btu/h 26700 24700 22600 20500 18500 16400 14500
25
30
35
40
45
50
55
Watts 1730 1850 1960 2070 2160 2240 2290 Amps 5.55 5.76 5.98 6.20 6.42 6.62 6.80
Lb/h 328 314 299 283 266 249 230
Btu/h 30100 27900 25700 23400 21200 19000 16800 Watts 1750 1890 2020 2150 2270 2370 2440 Amps 5.60 5.84 6.11 6.37 6.64 6.89 7.12
Lb/h 367 353 337 321 304 285 266
Btu/h 33700 31300 29000 26600 24200 21800 19400 Watts 1760 1920 2070 2220 2360 2480 2580 Amps 5.63 5.91 6.22 6.53 6.84 7.14 7.42
Lb/h 408 394 378 361 344 325 305
Btu/h 37500 35000 32500 29900 27300 24800 22200 Watts 1770 1940 2120 2290 2450 2590 2720 Amps 5.64 5.96 6.31 6.67 7.03 7.38 7.71
Lb/h 452 437 421 404 386 367 346
Btu/h 41600 38900 36200 33500 30700 28000 25300 Watts 1770 1960 2160 2340 2520 2690 2840 Amps 5.63 6.00 6.39 6.79 7.20 7.60 7.98
Lb/h 498 483 467 450 431 411 390
Btu/h 45800 43000 40200 37300 34400 31400 28500 Watts 1770 1980 2190 2400 2600 2780 2950 Amps 5.61 6.02 6.45 6.90 7.36 7.81 8.24
Lb/h 546 531 515 498 479 459 437
Btu/h 50400 47400 44400 41300 38200 35100 32000 Watts 1770 1990 2220 2440 2660 2870 3060 Amps 5.57 6.02 6.50 6.99 7.50 8.00 8.48
Lb/h 597 582 566 549 530 509 487
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 2.245686E+04 1.708123E+03 6.219072E+00 2.267478E+02 C2 6.190330E+02 -1.380474E+01 -1.642777E-02 5.989929E+00 C3 -8.520952E+01 -1.240705E+01 -4.001747E-02 -4.067298E-01 C4 4.109269E+00 -2.013652E-01 -4.708916E-04 2.741432E-02 C5 -1.569806E+00 3.081803E-01 4.311993E-04 1.150676E-03 C6 -6.208055E-01 1.849622E-01 4.392246E-04 -5.390359E-03 C7 7.119431E-03 1.978236E-03 6.350502E-07 5.836025E-05 C8 -4.226453E-03 -1.550990E-03 5.963690E-07 1.534388E-04 C9 -6.689560E-03 1.006639E-03 2.039677E-06 -9.075947E-05
C10 2.580273E-03 -8.386266E-04 -1.563698E-06 9.155064E-06
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature
Loading...