Performance Data Sheet
AWF5522EXT
General Information
Model AWF5522EXT Refrigerant R22
Test Condition ARI Test Voltage 230V 3~ 60HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type 3PH
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140 150
Btu/h 5630 4650
Watts 813 799
Amps 3.11 3.11
Lb/h 72.9 62.4
Btu/h 6930 5930 4970
Watts 913 909 896
Amps 3.31 3.33 3.33
Lb/h 89.2 79.0 69.2
Btu/h 8350 7310 6310 5350
Watts 1000 1010 1010 994
Amps 3.48 3.52 3.54 3.53
Lb/h 107 96.8 87.1 77.3
Btu/h 9900 8810 7760 6740 5750
Watts 1080 1100 1110 1110 1090
Amps 3.62 3.68 3.73 3.75 3.72
Lb/h 126 116 106 96.4 86.2
Btu/h 11600 10400 9330 8240 7170
Watts 1140 1170 1200 1210 1210
Amps 3.75 3.83 3.90 3.95 3.96
Lb/h 146 136 127 117 106
Btu/h 13400 12200 11000 9850 8700 7550 6390
Watts 1200 1240 1280 1300 1320 1320 1290
Amps 3.84 3.95 4.05 4.13 4.18 4.16 4.06
Lb/h 168 158 149 139 128 117 104
Btu/h 15500 14200 12900 11600 10300 9090 7820
Watts 1240 1300 1350 1390 1420 1430 1430
Amps 3.92 4.05 4.18 4.30 4.38 4.41 4.36
Lb/h 192 182 172 162 151 139 126
Btu/h 17700 16300 14900 13500 12100 10700 9360 7950
Watts 1270 1340 1410 1470 1510 1540 1550 1540
Amps 3.98 4.13 4.29 4.44 4.56 4.64 4.64 4.55
Lb/h 218 208 198 187 176 163 150 135
Btu/h 20100 18600 17000 15500 14000 12500 11000 9470
25
30
35
40
45
50
55
Watts 1290 1380 1460 1540 1600 1640 1670 1680
Amps 4.02 4.19 4.38 4.57 4.73 4.85 4.91 4.88
Lb/h 247 236 225 214 202 189 175 159
Btu/h 22800 21100 19400 17800 16100 14500 12800 11100
Watts 1300 1410 1510 1600 1670 1740 1780 1810
Amps 4.04 4.24 4.46 4.68 4.89 5.06 5.17 5.20
Lb/h 277 266 255 243 231 217 202 185
Btu/h 25700 23800 22000 20200 18400 16600 14700 12900
Watts 1300 1430 1540 1650 1740 1820 1890 1930
Amps 4.04 4.27 4.52 4.78 5.03 5.25 5.41 5.51
Lb/h 311 299 287 275 261 247 231 213
Btu/h 28800 26800 24800 22800 20800 18800 16800 14800
Watts 1290 1430 1570 1690 1810 1900 1990 2050
Amps 4.03 4.28 4.57 4.87 5.16 5.43 5.65 5.80
Lb/h 347 334 322 308 294 279 262 243
Btu/h 32200 30000 27800 25700 23500 21300 19100 16900
Watts 1270 1430 1580 1730 1860 1980 2080 2170
Amps 4.01 4.29 4.61 4.94 5.28 5.60 5.88 6.09
Lb/h 385 372 359 345 329 313 295 275
Btu/h 35900 33500 31100 28700 26400 24000 21600 19100
Watts 1240 1420 1590 1760 1910 2050 2170 2280
Amps 3.98 4.28 4.63 5.01 5.39 5.76 6.10 6.37
Lb/h 427 413 399 384 367 350 330 309
Btu/h 39800 37200 34600 32100 29500 26900 24200 21500
Watts 1200 1400 1590 1780 1950 2110 2260 2380
Amps 3.93 4.27 4.65 5.07 5.50 5.92 6.31 6.65
Lb/h 472 457 442 426 408 389 369 346
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 2.136694E+04 9.649680E+02 5.209072E+00 2.402555E+02
C2 3.976911E+02 -3.040282E+00 3.537917E-02 3.280606E+00
C3 -1.869829E+02 -2.252933E+00 -6.741720E-02 -2.170736E+00
C4 5.292776E+00 -3.492982E-01 -6.010509E-04 4.754004E-02
C5 -7.388094E-01 1.917669E-01 -5.746518E-04 1.354211E-02
C6 6.897440E-01 8.219917E-02 8.690408E-04 1.283845E-02
C7 1.980388E-02 2.080018E-04 1.782445E-06 2.144040E-04
C8 -2.962502E-02 1.513597E-03 1.530651E-06 -2.027281E-04
C9 -2.303512E-03 2.929269E-04 5.800969E-06 -6.797183E-05
C10 -1.803273E-03 -4.547688E-04 -3.423693E-06 -4.537258E-05
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature