Performance Data Sheet
AWF5522EVA
General Information
Model AWF5522EVA Refrigerant R-22
Test Condition ARI Performance Test Voltage 220V ~ 50HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type PSC
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 4860 3970
Watts 787 767
Amps 3.46 3.48
Lb/h 62.3 53.1
Btu/h 6070 5150 4260
Watts 848 841 828
Amps 3.79 3.86 3.86
Lb/h 77.7 68.5 59.4
Btu/h 7330 6370 5440 4550
Watts 901 907 907 899
Amps 4.08 4.19 4.23 4.21
Lb/h 93.4 84.3 75.0 65.8
Btu/h 8660 7650 6670 5720 4840
Watts 945 965 979 984 979
Amps 4.31 4.46 4.56 4.59 4.56
Lb/h 110 101 91.2 81.9 72.6
Btu/h 10100 9010 7970 6960 6000
Watts 981 1010 1040 1060 1070
Amps 4.50 4.70 4.84 4.93 4.96
Lb/h 127 118 108 98.7 89.1
Btu/h 11600 10500 9360 8280 7240 6270 5380
Watts 1010 1060 1100 1130 1150 1170 1160
Amps 4.63 4.89 5.09 5.23 5.32 5.36 5.33
Lb/h 145 136 126 116 107 97.0 87.7
Btu/h 13200 12000 10900 9700 8580 7520 6530
Watts 1030 1090 1150 1190 1230 1260 1270
Amps 4.73 5.04 5.29 5.50 5.65 5.75 5.80
Lb/h 164 155 145 135 125 115 105
Btu/h 15000 13700 12500 11200 10000 8870 7780
Watts 1040 1120 1190 1250 1300 1340 1370
Amps 4.78 5.15 5.46 5.73 5.95 6.12 6.24
Lb/h 185 176 166 156 145 135 125
Btu/h 16900 15600 14200 12900 11600 10300 9150
25
30
35
40
45
50
55
Watts 1040 1130 1220 1300 1360 1420 1460
Amps 4.80 5.22 5.60 5.93 6.22 6.46 6.66
Lb/h 207 198 188 178 167 156 145
Btu/h 19000 17600 16200 14700 13300 12000 10600
Watts 1040 1140 1240 1340 1420 1490 1550
Amps 4.77 5.25 5.70 6.10 6.46 6.78 7.05
Lb/h 232 222 212 202 191 179 168
Btu/h 21300 19800 18300 16700 15200 13700 12300
Watts 1030 1150 1260 1370 1470 1550 1630
Amps 4.71 5.26 5.77 6.24 6.68 7.07 7.43
Lb/h 258 248 238 227 216 204 193
Btu/h 23800 22200 20500 18900 17300 15700 14100
Watts 1010 1140 1270 1390 1510 1610 1700
Amps 4.61 5.23 5.81 6.36 6.87 7.34 7.78
Lb/h 286 277 267 255 244 232 220
Btu/h 26500 24800 23000 21300 19500 17800 16100
Watts 979 1130 1280 1410 1540 1660 1770
Amps 4.49 5.17 5.83 6.45 7.04 7.60 8.12
Lb/h 317 308 297 286 274 262 249
Btu/h 29500 27600 25800 23900 22000 20100 18300
Watts 944 1110 1270 1430 1570 1700 1830
Amps 4.33 5.09 5.82 6.52 7.20 7.84 8.45
Lb/h 351 341 331 319 307 294 281
Btu/h 32700 30700 28700 26700 24700 22700 20700
Watts 902 1080 1260 1430 1590 1740 1880
Amps 4.15 4.98 5.79 6.57 7.33 8.07 8.77
Lb/h 387 377 367 355 342 329 315
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 1.527718E+04 7.522782E+02 9.992498E-01 1.549505E+02
C2 3.110689E+02 -1.314044E+01 -9.247846E-03 2.715433E+00
C3 -4.497015E+01 6.377169E-01 6.349151E-02 -3.922398E-02
C4 2.718073E+00 -1.978054E-01 -1.397407E-03 1.618056E-02
C5 5.830224E-03 2.556530E-01 3.731000E-04 1.511731E-02
C6 -7.153590E-01 4.545215E-02 -2.655663E-04 -8.924688E-03
C7 2.294686E-02 1.485260E-04 2.810621E-06 2.743942E-04
C8 -1.273791E-02 3.790355E-04 5.367413E-06 -5.196705E-06
C9 -5.914178E-03 1.066313E-04 3.317693E-06 -9.106386E-05
C10 3.041491E-03 -2.919553E-04 -1.338201E-07 2.945716E-05
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature