Performance Data Sheet
AWF5519EVA
General Information
Model AWF5519EVA Refrigerant R-22
Test Condition ARI Performance Test Voltage 220V ~ 50HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type PSC
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 3590 2830
Watts 635 593
Amps 2.89 2.77
Lb/h 46.2 38.1
Btu/h 4710 3910 3090
Watts 696 671 636
Amps 3.18 3.12 2.99
Lb/h 60.3 52.2 43.2
Btu/h 5920 5070 4210 3320
Watts 749 741 723 693
Amps 3.43 3.45 3.38 3.24
Lb/h 75.4 67.2 58.1 48.2
Btu/h 7240 6330 5400 4460 3510
Watts 795 803 801 789 763
Amps 3.65 3.73 3.73 3.66 3.53
Lb/h 91.5 83.2 74.0 63.9 52.8
Btu/h 8670 7690 6690 5690 4670
Watts 832 857 872 876 867
Amps 3.83 3.98 4.05 4.05 3.99
Lb/h 109 100 91.0 80.7 69.4
Btu/h 10200 9160 8090 7010 5910 4810 3710
Watts 862 903 934 955 962 955 932
Amps 3.97 4.19 4.33 4.40 4.41 4.37 4.28
Lb/h 128 119 109 98.6 87.0 74.3 60.4
Btu/h 11900 10800 9600 8430 7250 6070 4880
Watts 884 941 989 1030 1050 1060 1050
Amps 4.08 4.36 4.57 4.71 4.80 4.83 4.81
Lb/h 148 139 129 118 106 92.9 78.6
Btu/h 13800 12500 11200 9970 8690 7420 6140
Watts 898 971 1040 1090 1130 1150 1160
Amps 4.15 4.50 4.77 4.99 5.15 5.25 5.31
Lb/h 170 160 150 138 126 113 98.1
Btu/h 15800 14400 13000 11600 10300 8870 7490
25
30
35
40
45
50
55
Watts 905 994 1070 1140 1200 1240 1260
Amps 4.18 4.60 4.94 5.23 5.46 5.64 5.78
Lb/h 193 183 172 160 148 134 119
Btu/h 17900 16400 14900 13400 11900 10400 8950
Watts 904 1010 1100 1190 1260 1320 1360
Amps 4.18 4.66 5.07 5.43 5.73 5.99 6.20
Lb/h 219 208 196 184 171 157 141
Btu/h 20300 18700 17000 15400 13800 12200 10500
Watts 896 1020 1130 1230 1310 1390 1440
Amps 4.14 4.69 5.17 5.59 5.97 6.29 6.58
Lb/h 246 235 223 210 196 181 165
Btu/h 22900 21100 19300 17500 15800 14000 12200
Watts 881 1020 1140 1260 1360 1450 1520
Amps 4.07 4.68 5.23 5.72 6.16 6.57 6.93
Lb/h 275 263 251 237 223 207 190
Btu/h 25600 23700 21800 19800 17900 16000 14100
Watts 858 1010 1150 1280 1400 1500 1590
Amps 3.96 4.63 5.25 5.81 6.33 6.80 7.24
Lb/h 307 294 281 267 251 235 218
Btu/h 28600 26500 24400 22300 20200 18200 16100
Watts 827 993 1150 1290 1430 1540 1650
Amps 3.82 4.55 5.23 5.86 6.45 7.00 7.51
Lb/h 341 327 313 298 282 265 247
Btu/h 31800 29600 27300 25000 22800 20500 18300
Watts 790 970 1140 1300 1450 1580 1700
Amps 3.64 4.44 5.18 5.88 6.54 7.16 7.74
Lb/h 377 363 348 332 315 297 278
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 1.369656E+04 5.793454E+02 -5.196458E-01 1.426686E+02
C2 3.911830E+02 -1.821316E+01 -5.247284E-02 3.694867E+00
C3 -6.951260E+01 2.394809E+00 9.810916E-02 -5.970045E-01
C4 4.038554E+00 -1.287288E-01 -6.691098E-04 3.485395E-02
C5 -1.620027E+00 3.301572E-01 9.743239E-04 -4.852327E-03
C6 -1.652197E-01 2.547258E-02 -6.531225E-04 9.434215E-04
C7 1.563168E-02 6.540458E-05 1.772016E-07 1.643522E-04
C8 -2.180344E-02 -3.345436E-04 -7.844501E-07 -1.297195E-04
C9 1.924207E-03 1.012117E-05 2.200569E-06 6.855960E-06
C10 3.095569E-04 -2.721426E-04 9.724544E-07 -1.840503E-05
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature