General Information
Model AWF5517EXN Refrigerant R-22
Test Condition ARI Performance Test Voltage 230V ~ 60HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type PSC
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 4020 3600
Watts 642 659
Amps 2.98 3.03
Lb/h 51.9 48.4
Btu/h 4800 4250 3700
Watts 696 714 718
Amps 3.20 3.26 3.27
Lb/h 61.6 56.8 51.5
Btu/h 5800 5130 4450 3750
Watts 750 771 778 773
Amps 3.42 3.50 3.52 3.50
Lb/h 74.0 68.0 61.5 54.1
Btu/h 7030 6220 5410 4590 3750
Watts 803 829 840 839 825
Amps 3.63 3.74 3.78 3.77 3.72
Lb/h 89.0 81.9 74.2 65.7 56.1
Btu/h 8480 7530 6580 5620 4660
Watts 854 886 903 907 898
Amps 3.84 3.97 4.05 4.06 4.03
Lb/h 107 98.4 89.6 80.0 69.3
Btu/h 10100 9050 7960 6870 5760 4650 3520
Watts 900 941 966 977 975 961 939
Amps 4.03 4.20 4.31 4.35 4.35 4.30 4.23
Lb/h 127 117 108 96.9 85.1 72.0 57.3
Btu/h 12000 10800 9550 8310 7070 5820 4550
Watts 942 992 1030 1050 1050 1050 1030
Amps 4.20 4.41 4.56 4.64 4.67 4.65 4.60
Lb/h 149 139 128 116 104 89.4 73.6
Btu/h 14100 12700 11300 9950 8560 7170 5770
Watts 976 1040 1080 1110 1130 1130 1130
Amps 4.34 4.61 4.80 4.92 4.99 5.01 5.00
Lb/h 174 162 151 138 124 109 92.6
Btu/h 16300 14800 13300 11800 10200 8710 7160
25
30
35
40
45
50
55
Watts 1000 1080 1140 1180 1210 1220 1230
Amps 4.45 4.77 5.02 5.19 5.31 5.37 5.39
Lb/h 200 188 176 162 148 132 114
Btu/h 18800 17100 15500 13800 12100 10400 8730
Watts 1020 1110 1180 1240 1280 1310 1320
Amps 4.52 4.90 5.21 5.44 5.61 5.73 5.80
Lb/h 229 216 203 189 173 156 138
Btu/h 21400 19600 17800 16000 14100 12300 10500
Watts 1030 1130 1220 1300 1350 1390 1420
Amps 4.54 5.00 5.37 5.67 5.90 6.07 6.19
Lb/h 260 247 232 217 201 183 164
Btu/h 24300 22300 20300 18300 16400 14400 12400
Watts 1020 1150 1250 1340 1420 1470 1520
Amps 4.52 5.05 5.50 5.86 6.16 6.40 6.58
Lb/h 293 279 264 248 231 213 193
Btu/h 27300 25200 23000 20900 18700 16600 14500
Watts 1000 1150 1270 1380 1470 1550 1610
Amps 4.44 5.05 5.58 6.03 6.40 6.70 6.95
Lb/h 327 312 297 281 263 244 223
Btu/h 30500 28200 25900 23600 21300 19000 16700
Watts 966 1130 1280 1410 1520 1620 1700
Amps 4.29 5.00 5.62 6.14 6.59 6.98 7.30
Lb/h 363 348 332 315 297 277 256
Btu/h 33800 31400 28900 26400 24000 21500 19100
Watts 914 1110 1280 1430 1560 1680 1780
Amps 4.08 4.89 5.60 6.22 6.75 7.22 7.62
Lb/h 401 385 369 351 333 312 290
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 1.351200E+04 -1.188406E+02 -4.636889E-01 1.537408E+02
C2 4.902042E+02 -3.145012E+00 -2.565651E-02 4.904975E+00
C3 -8.361749E+01 2.136360E+01 9.828863E-02 -1.186842E+00
C4 4.810296E+00 -3.255856E-01 -1.284656E-03 4.125704E-02
C5 -2.863646E+00 2.183596E-01 1.131751E-03 -1.910614E-02
C6 6.018276E-02 -1.439915E-01 -7.085484E-04 7.931541E-03
C7 -6.280328E-03 -1.859951E-03 -7.605741E-06 -1.256555E-04
C8 -5.829081E-03 3.442407E-03 1.348008E-05 1.183945E-04
C9 9.919167E-04 -6.119709E-04 -3.498104E-06 -1.784866E-05
C10 -3.432325E-04 2.626950E-04 1.502326E-06 -4.016656E-05
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature