Performance Data Sheet
AWF5516EXN
General Information
Model AWF5516EXN Refrigerant R-22
Test Condition ARI Performance Test Voltage 230V ~ 60HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type PSC
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 3950 3540
Watts 630 646
Amps 2.93 2.98
Lb/h 51.0 47.5
Btu/h 4710 4180 3630
Watts 683 700 704
Amps 3.15 3.21 3.22
Lb/h 60.5 55.8 50.6
Btu/h 5700 5040 4370 3690
Watts 736 756 763 758
Amps 3.37 3.45 3.47 3.45
Lb/h 72.6 66.8 60.4 53.2
Btu/h 6900 6110 5310 4500 3680
Watts 788 813 824 822 809
Amps 3.58 3.68 3.73 3.72 3.67
Lb/h 87.4 80.4 72.9 64.5 55.1
Btu/h 8320 7400 6460 5520 4570
Watts 837 869 886 889 881
Amps 3.78 3.92 3.98 4.00 3.97
Lb/h 105 96.6 88.0 78.5 68.0
Btu/h 9950 8890 7820 6740 5660 4570 3460
Watts 883 923 947 958 956 943 921
Amps 3.97 4.14 4.24 4.29 4.28 4.24 4.16
Lb/h 124 115 106 95.1 83.6 70.7 56.2
Btu/h 11800 10600 9370 8160 6940 5710 4470
Watts 924 973 1010 1030 1030 1030 1010
Amps 4.14 4.35 4.49 4.57 4.60 4.59 4.54
Lb/h 146 136 126 114 102 87.7 72.3
Btu/h 13800 12500 11100 9770 8410 7040 5660
Watts 957 1020 1060 1090 1110 1110 1110
Amps 4.28 4.54 4.73 4.85 4.92 4.94 4.92
Lb/h 170 160 148 136 122 107 90.9
Btu/h 16000 14500 13100 11600 10100 8550 7030
25
30
35
40
45
50
55
Watts 984 1060 1120 1160 1180 1200 1200
Amps 4.38 4.70 4.94 5.11 5.23 5.29 5.31
Lb/h 197 185 173 159 145 129 112
Btu/h 18500 16800 15200 13500 11900 10200 8570
Watts 1000 1090 1160 1220 1260 1280 1300
Amps 4.45 4.83 5.13 5.36 5.53 5.64 5.71
Lb/h 225 213 199 185 170 154 135
Btu/h 21100 19300 17500 15700 13900 12100 10300
Watts 1010 1110 1200 1270 1330 1370 1390
Amps 4.47 4.93 5.29 5.58 5.81 5.98 6.10
Lb/h 255 242 228 213 197 180 161
Btu/h 23800 21900 20000 18000 16100 14100 12200
Watts 1000 1120 1230 1320 1390 1450 1490
Amps 4.45 4.98 5.42 5.78 6.07 6.30 6.48
Lb/h 287 274 259 244 227 209 189
Btu/h 26800 24700 22600 20500 18400 16300 14200
Watts 981 1130 1250 1360 1450 1520 1580
Amps 4.37 4.98 5.50 5.94 6.30 6.60 6.85
Lb/h 321 307 292 276 258 239 219
Btu/h 29900 27700 25400 23200 20900 18600 16400
Watts 947 1110 1260 1380 1490 1590 1670
Amps 4.23 4.93 5.53 6.05 6.50 6.87 7.19
Lb/h 357 342 326 309 291 272 251
Btu/h 33200 30800 28400 26000 23600 21100 18700
Watts 897 1090 1250 1400 1530 1650 1750
Amps 4.02 4.82 5.51 6.12 6.65 7.11 7.51
Lb/h 394 378 362 345 327 307 285
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 1.326781E+04 -1.165405E+02 -4.567682E-01 1.509608E+02
C2 4.813451E+02 -3.084140E+00 -2.527358E-02 4.816284E+00
C3 -8.210633E+01 2.095011E+01 9.682163E-02 -1.165382E+00
C4 4.723363E+00 -3.192840E-01 -1.265482E-03 4.051104E-02
C5 -2.811893E+00 2.141333E-01 1.114860E-03 -1.876066E-02
C6 5.909512E-02 -1.412046E-01 -6.979730E-04 7.788124E-03
C7 -6.166828E-03 -1.823952E-03 -7.492222E-06 -1.233834E-04
C8 -5.723736E-03 3.375779E-03 1.327888E-05 1.162537E-04
C9 9.739906E-04 -6.001263E-04 -3.445893E-06 -1.752592E-05
C10 -3.370295E-04 2.576106E-04 1.479903E-06 -3.944027E-05
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature