Performance Data Sheet
AWF5516EVA
General Information
Model AWF5516EVA Refrigerant R-22
Test Condition ARI Performance Test Voltage 220V ~ 50HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type PSC
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 3480 2870
Watts 550 527
Amps 2.67 2.54
Lb/h 44.8 38.5
Btu/h 4330 3690 3020
Watts 604 594 570
Amps 2.92 2.86 2.73
Lb/h 55.5 49.2 42.1
Btu/h 5270 4590 3880 3160
Watts 651 654 643 618
Amps 3.13 3.13 3.08 2.95
Lb/h 67.2 60.8 53.5 45.6
Btu/h 6310 5580 4810 4040 3270
Watts 691 706 708 697 674
Amps 3.31 3.37 3.38 3.33 3.21
Lb/h 79.9 73.3 65.9 57.8 49.1
Btu/h 7440 6650 5830 5000 4170
Watts 724 752 767 769 759
Amps 3.45 3.58 3.65 3.67 3.62
Lb/h 93.7 86.9 79.3 70.9 62.0
Btu/h 8690 7840 6950 6050 5160 4290 3480
Watts 749 791 819 834 838 831 814
Amps 3.56 3.74 3.88 3.97 4.00 3.95 3.84
Lb/h 109 102 93.8 85.1 75.9 66.4 56.7
Btu/h 10100 9140 8170 7200 6230 5290 4400
Watts 767 823 864 893 911 917 914
Amps 3.63 3.87 4.08 4.23 4.33 4.37 4.33
Lb/h 125 118 110 101 91.0 81.1 71.0
Btu/h 11600 10600 9510 8450 7400 6370 5400
Watts 778 848 903 946 977 998 1010
Amps 3.67 3.97 4.24 4.46 4.63 4.74 4.79
Lb/h 143 135 127 117 107 97.0 86.4
Btu/h 13200 12100 11000 9830 8680 7560 6490
25
30
35
40
45
50
55
Watts 782 866 935 992 1040 1070 1100
Amps 3.68 4.04 4.37 4.66 4.90 5.08 5.20
Lb/h 162 154 145 135 125 114 103
Btu/h 15000 13800 12600 11300 10100 8860 7680
Watts 780 877 961 1030 1090 1140 1180
Amps 3.66 4.08 4.47 4.82 5.13 5.38 5.58
Lb/h 183 175 165 155 144 133 121
Btu/h 17000 15700 14300 13000 11600 10300 8990
Watts 770 881 980 1070 1140 1200 1260
Amps 3.62 4.09 4.53 4.95 5.32 5.65 5.93
Lb/h 205 197 187 176 165 153 141
Btu/h 19100 17700 16200 14700 13300 11800 10400
Watts 753 879 992 1090 1180 1260 1330
Amps 3.55 4.07 4.57 5.05 5.49 5.89 6.24
Lb/h 230 221 211 199 187 175 162
Btu/h 21400 19900 18300 16700 15100 13500 12000
Watts 729 870 998 1110 1220 1310 1390
Amps 3.46 4.03 4.59 5.12 5.63 6.10 6.53
Lb/h 256 247 236 224 211 198 185
Btu/h 23900 22200 20500 18800 17000 15300 13700
Watts 698 854 997 1130 1250 1350 1450
Amps 3.35 3.97 4.58 5.17 5.74 6.28 6.78
Lb/h 285 274 263 251 237 224 210
Btu/h 26600 24800 22900 21100 19200 17300 15500
Watts 660 832 990 1140 1270 1390 1510
Amps 3.21 3.88 4.54 5.20 5.83 6.43 7.00
Lb/h 315 304 292 279 265 251 236
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 8.435518E+03 -5.467547E+01 1.771134E+00 7.504154E+01
C2 2.969679E+02 -1.330683E+01 -3.589718E-02 2.675328E+00
C3 3.996520E+01 1.745660E+01 2.145781E-02 9.457204E-01
C4 3.397542E+00 -1.780818E-01 -5.085975E-04 2.862954E-02
C5 -9.440298E-01 2.537777E-01 4.826006E-04 2.182620E-03
C6 -1.114090E+00 -1.153707E-01 7.538289E-05 -1.384599E-02
C7 1.258588E-02 3.853326E-05 2.152785E-06 1.350275E-04
C8 -1.647376E-02 4.295001E-04 -2.724969E-06 -7.908468E-05
C9 -7.499121E-04 3.683416E-05 4.518799E-06 -3.228589E-05
C10 3.521285E-03 1.708312E-04 -1.287174E-06 3.472334E-05
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature