35.38
36.25
23.30
25.50
26.08
4.24
34.62
SUCTION
5
8
"
LIQUID
3
8
"
26.43
Factory charge 20 psig dry air, MUST BE EVACUATED
Ambient Temperatures
80°F 90°F 100°F 110°F
T, °F PSIG BTUH Watts Head Cond T BTUH Watts Head Cond T BTUH Watts Head Cond T BTUH Watts Head Cond T
-10 23.9 7410 1580 200 89 6420 1530 227 97 5410 1490 258 106 4380 1440 292 115
-5 28.2 8870 1710 205 91 7750 1680 233 99 6630 1650 264 108 5480 1610 298 117
0 32.8 10340 1840 211 92 9100 1820 239 101 7860 1800 269 109 6600 1780 303 118
5 37.9 11820 1960 217 94 10470 1950 245 103 9120 1940 275 111 7750 1930 309 119
10 42.4 13310 2070 223 96 11850 2070 251 104 10400 2070 281 113 8920 2070 315 121
15 48.2 14810 2170 230 98 13250 2190 258 106 11690 2200 288 114 10120 2210 321 122
20 54.5 16320 2270 237 100 14660 2290 264 108 13010 2320 295 116 11350 2340 327 124
25 61.2 17840 2360 244 102 16090 2390 272 110 14350 2430 302 118 12610 2460 334 125
30 68.4 19370 2450 252 105 17540 2490 280 112 15710 2530 309 120 13890 2570 342 127
35 76.1 20900 2530 260 107 18990 2570 288 114 17100 2620 318 122 15200 2670 349 129
40 84.4 22450 2600 269 109 20470 2650 297 117 18500 2710 326 124 16530 2770 358 131
PRELIMINARY
Performance @ 60 Hz, Return gas 40oF below 20oF Evaporator and 65oF above 20oF evaporator, SubCooling 5oF
TECUMSEH OUTDOOR
CONDENSING UNIT
Model AWA9515ZXTHN
BOM 32L3252-2E*
Air Cooled 1 ¾ HP
Application Commercial Temp
Refrigerant R404A
Volts-Hz-Ph 200-230/60/3
AWA9515ZXTHN_Rev 1
TPC - March 16, 2016
* OPTION CODE: See reverse side for Available Options
Unit BOM 32L3252-2E Fan Motor 810F050C20
Unit MODEL AWA9515ZXTHN Replacement Fan Motor 810F050C20(C) 32Lxxxx-2ER(F)ATnD
Fan Motor Qty 2 R Heated/Insulated Receiver
Refrigeration Range -10°F to 45°F Fan Motor RLA 0.7 F Fixed Fan Control
Design Pressure Low / High 181 / 450 Fan Blade 51568-1 A Adjustable Fan Control
Volts - HZ - Ph 200-230/60/3 Fan Guard 70831 T1 Air Defrost Timer
Voltage Range 180 - 253 Shroud 70648-2 T2 Electrical Defrost Timer & Defrost
Min. Circuit Ampacity 11.31 Heater Contactor
Max. Fuse Size 20 High Pressure Switch 84095-2L D Disconnect Switch (nonfused)
Low Pressure Control 84026-2
Compressor MODEL AWA9512ZXT Dual Pressure Conrol
Compressor BOM AW611ST-120-J7
Compressor LRA 50 Head Master Valve 70083 Solenoid Valve (supplied loose) KSVC-264
Compressor RLA 7.76 Check Valve 56626 Hail Louver Assy LLPG-201
Process Valve
OverLoad Internal Discharge Valve (Base) 56618
Replacement Kit - O/L Liquid Valve (Base) 56500-K06 Receiver Heater (R option) 92124-2
Relay Liquid Valve (Receiver) attached Receiver Thermostat (R option) 84102-2
Replacement Kit - Relay Suction Valve (Base) 56500-K14 Fixed Fan Control (F option) 84132-1
Run Capacitor Suction Valve (Rotolock) 31583-1 Adjustable Fan Control (A option)
Replacement Kit - Run Cap.
Start Capacitor Condenser 50858-1 Defrost Timer (T1 or T2 option) 84110
Replacement Kit - St. Cap. Receiver 51099-2L Defrost Heater Contactor and 91014H and
Contactor 91014H Accumulator TK00042000 Auxiliary Switch (T2 opt.) 91014-AUH
Liquid Filter 70139
Unit Drawing DGU1918-L303 Sight Glass 70084-S Disconnect (D option)
Wiring Diagram WD23-2XT2 Suction Filter 70822-5S
Wiring Diagram (A or F opt.) WD23-2AT2 CrankCase Heater 91022-1
AWA9515ZXTHN_Rev 1
TPC - March 16, 2016