Model: AWA9511ZXNXF      BoM: 2B1167-1      R-404A      1.5 HP      AIRCOOLED 
Model 
AWA9511ZXNXF 
* F = Flare, S = Solder, RF or RS = Rotolock with Flare or Solder Connections, C = Compression Fitting 
Evaporator T 
°F PSIG BTUH Watts Cond T BTUH Watts Cond T BTUH  Watts  Cond T  BTUH  Watts  Cond T 
-5 28.1 5986 1514 98 5482 1501 103 4711 1481 110 3659 1455 119 
0  32.8 6872 1614 100 6366 1603 104 5555 1587 111 4386 1567 120 
5  37.9 7890 1714 101 7367 1705 106 6501 1693 112 5210 1681 121 
10  43.3 9036 1811 103 8482 1805 107 7549 1799 114 6133 1796 123 
15  49.1 10314 1908 104 9714 1906 109 8699 1906 115 7153 1911 124 
20 55.5 11723 2004 106 11062 2006 110 9951 2013 117 8272 2028 126 
25 62.2 13261 2099 108 12525 2106 112 11306 2120 119 9488 2145 128 
30 69.5 14930 2192 110 14104 2205 114 12762 2227 121 10803 2263 129 
35 77.2 16730 2285 112 15799 2303 116 14321 2334 122 12216 2382 131 
40 85.5 18661 2376 114 17610 2401 118 15982 2442 124 13726 2502 133 
45 94.3 20721 2466 116 19536 2498 120 17745 2550 126 15335 2623 135 
25.0  33.5  19.5  14.7  7/8” S  3/8” S  16.46 lbs  1850  38.5  190 
Dimensions, inches  Line Connection*  Pumpdown  Air  Oil Ch  Gr. Wt. 
L W H CH Suction Liquid 
80F  90F  100F  110F 
Return gas temp. 40F Evaporator Temp. 20F or less, 5F sub-cooling 
Return gas temp. 65F for Evaporator Temp. > 20F, 5F sub-cooling 
90 F 90% 
Ambient Temperatures 
SCFM Oz. Lbs. 