Performance Data Sheet
AWA9490ZXC
General Information
Model AWA9490ZXC Refrigerant R-404A
Test Condition ARI Performance Test Voltage 240V ~ 50HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type CSR
Performance Information
Evap Temp (°F)
20
25
30
35
40
45
50
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 15700 14000 12300 10600 8910 7180 5420
Watts 1400 1430 1450 1480 1500 1530 1550
Amps 7.56 7.63 7.69 7.75 7.82 7.89 7.96
Lb/h 259 243 227 210 193 176 158
Btu/h 17800 15900 14100 12200 10300 8400 6490
Watts 1430 1470 1510 1550 1590 1620 1660
Amps 7.63 7.76 7.88 8.00 8.11 8.23 8.34
Lb/h 292 275 258 241 224 207 189
Btu/h 20100 18000 15900 13800 11700 9680 7600
Watts 1450 1510 1570 1620 1670 1720 1770
Amps 7.65 7.85 8.05 8.23 8.40 8.57 8.73
Lb/h 328 311 294 276 259 241 223
Btu/h 22500 20200 17900 15600 13300 11000 8780
Watts 1460 1540 1610 1680 1740 1810 1870
Amps 7.61 7.90 8.17 8.43 8.67 8.90 9.12
Lb/h 369 351 333 315 297 279 261
Btu/h 25100 22500 20000 17500 15000 12500 10000
Watts 1450 1550 1640 1730 1810 1890 1970
Amps 7.50 7.88 8.24 8.58 8.90 9.21 9.49
Lb/h 413 395 376 358 340 321 303
Btu/h 28000 25100 22300 19600 16800 14100 11400
Watts 1430 1540 1660 1760 1870 1970 2060
Amps 7.29 7.78 8.24 8.67 9.08 9.46 9.83
Lb/h 462 443 424 405 386 367 348
Btu/h 31100 28000 24900 21800 18800 15900 13000
Watts 1380 1520 1660 1790 1910 2030 2140
Amps 6.98 7.58 8.14 8.68 9.18 9.66 10.1
Lb/h 516 496 476 456 437 417 397
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 1.548161E+04 1.485241E+03 8.486768E+00 2.850581E+02
C2 6.314678E+02 -1.188812E+01 -6.102376E-02 3.599876E+00

C3 -8.752124E+01 -3.467607E+00 -1.946073E-02 -1.452331E+00
C4 2.738405E+00 -1.616225E-01 -7.640323E-04 8.078101E-02
C5 -4.082875E+00 3.057102E-01 1.327489E-03 -9.289803E-03
C6 -1.672371E-03 4.693547E-03 1.754273E-05 4.253251E-04
C7 3.843066E-02 -3.678052E-03 -2.157667E-05 1.869530E-04
C8 -3.501116E-02 3.129013E-03 1.894927E-05 -1.897319E-04
C9 9.875392E-03 -8.241737E-04 -5.161172E-06 5.866841E-05
C10 -8.336332E-04 2.963035E-05 2.918872E-07 -8.744275E-06
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature

Performance Data Sheet
AWA9490ZXC
General Information
Model AWA9490ZXC Refrigerant R-404A
Test Condition ARI Performance Test Voltage 240V ~ 50HZ
Return Gas 4.4°C (40°F) RETURN GAS Motor Type CSR
Performance Information
Evap Temp (°F)
0
5
10
15
20
25
30
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 8260 7230 6200 5180 4160 3140 2130
Watts 1240 1220 1200 1170 1150 1130 1100
Amps 7.07 6.98 6.89 6.80 6.71 6.61 6.52
Lb/h 152 139 126 113 100 87.4 74.3
Btu/h 9720 8520 7320 6130 4940 3760 2580
Watts 1290 1280 1270 1250 1240 1230 1210
Amps 7.22 7.17 7.12 7.06 7.01 6.95 6.89
Lb/h 174 160 146 131 117 102 87.8
Btu/h 11300 9940 8580 7210 5860 4500 3150
Watts 1340 1340 1340 1340 1340 1330 1320
Amps 7.37 7.36 7.34 7.33 7.31 7.29 7.26
Lb/h 202 187 171 156 140 124 108
Btu/h 13000 11500 9970 8440 6910 5380 3860
Watts 1400 1410 1420 1430 1430 1440 1440
Amps 7.52 7.54 7.57 7.59 7.60 7.62 7.63
Lb/h 234 218 202 186 169 152 135
Btu/h 14900 13200 11500 9800 8100 6400 4710
Watts 1440 1470 1490 1510 1530 1550 1560
Amps 7.66 7.73 7.79 7.84 7.90 7.95 8.00
Lb/h 270 253 237 219 202 184 166
Btu/h 16900 15100 13200 11300 9440 7570 5710
Watts 1480 1520 1550 1590 1620 1650 1680
Amps 7.80 7.90 8.00 8.10 8.19 8.28 8.37
Lb/h 308 291 274 256 239 221 202
Btu/h 19100 17100 15000 13000 10900 8880 6850
Watts 1500 1550 1600 1650 1700 1740 1790
Amps 7.93 8.07 8.21 8.34 8.48 8.61 8.73
Lb/h 347 330 313 296 278 260 241
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 1.654840E+04 1.391628E+03 7.761111E+00 2.549851E+02
C2 5.477386E+02 -5.951814E+00 -2.827594E-02 5.859039E+00

C3 -1.033227E+02 -2.031930E+00 -8.821439E-03 -1.300608E+00
C4 2.747400E+00 -4.611362E-02 -9.198966E-05 8.353648E-02
C5 -3.370278E+00 2.142649E-01 7.490974E-04 -2.009754E-02
C6 -1.065648E-02 3.394478E-03 5.032733E-06 2.473476E-04
C7 5.472743E-03 -5.400164E-03 -1.772736E-06 -1.351772E-03
C8 -1.500796E-03 2.101331E-03 9.593905E-07 5.598307E-04
C9 2.034494E-05 -1.932136E-04 -1.223578E-07 -5.803604E-05
C10 9.323356E-05 -2.630107E-05 -3.886480E-08 -1.243354E-06
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature