Tecumseh AWA2488ZXTXU User Manual

AWA2488ZXTXU
TECUMSEH HERMETIC
CONDENSING UNIT
Model AWA2488ZXTXU BOM 2W2002-1
Water Cooled 2 HP Application Low Temp Refrigerant R 404A
Model
AWA2488ZXTXU 24.3 17.9 17.2 14.3 7/8"S 3/8"F 5.1 38.0 119.0
*) Use 3/8" min. pipe size. Water inlet 3/8" NPT
L W H CH Suction Liquid
Dimensions, inches Line connection*
Pumdown Oil Ch Gr. Wt
90
o
Oz. Lbs.
Performance: Ambient 90
Evaporator temperature
Capacity BTU/HR
Water Usage gpm
Watts
The water valve should be adjusted to maintain a maximum of 95 condenser.
o
F -- Return Gas 40 oF -- Condenser water in 75 oF -- Head 254 PSIG
o
F
-40 -30 -20 -10 0 10
2046 3796 6024 8764 12047 15908
0.60 1.00 1.50 2.20 3.10 4.00
890 1191 1537 1891 2218 2483
o
F water outlet temperature in order to minimize water scaling within the
TPC___rev 02
October 21, 2003
C:\Projects\Proj_WaterCooled\WC Datasheets\LowTemp\AWA2488ZXTXU_2W2002-1.doc 21/10/2003
y
AWA2488ZXTXU
TPC___rev 02 October 21, 2003
Parts/Specifications
Unit BOM 2W2002-1 Unit MODEL AWA2488ZXTXU
Refrigeration RANGE -40F to +10F Run Capacitor Rating Design Pressure Low 181 Start Capacitor Design Pressure High 450 Start Capacitor Rating Volts - HZ - Ph 200-230-60-3 Contactor 91014 Min. Circuit Ampacity 10.9 Max. Fuse Size 20 High Pressure switch 84097-3
Compressor MODEL AWA2460ZXT Dual Pressure Conrol Compressor BOM AW613RT-121-A2 Compressor LRA 63.4 Condenser 50812-1 Compressor RLA 8.4 Water Valve 56516
Fan Motor NUT6B09PUN202 Suction Valve 31529-1 Fan Motor RLA 0.35 Fan Blade 51559-2
OverLoad internal Rela Run Capacitor
Low Pressure Control 84026-D
Liquid Valve 31547-8
Unit Drawing DGU1918-34W Receiver 51081 Electrical Drawing 91029-1 Accumulator TK00042000
C:\Projects\Proj_WaterCooled\WC Datasheets\LowTemp\AWA2488ZXTXU_2W2002-1.doc 21/10/2003