Tecumseh Compressor Company
March 16, 2011
Indoor Condensing Units
Model: AWA2457ZXDXF BoM: 2B3263-1 R-404A 1.5 HP AIRCOOLED
Model
AWA2457ZXDXF
* F = Flare, S = Solder, RF or RS = Rotolock with Flare or Solder Connections, C = Compression Fitting
Evaporator T
°F PSIG BTUH Watts Cond T BTUH Watts Cond T BTUH Watts Cond T BTUH Watts Cond T
-40 11.9 1960 954 85 1501 894 94 --- --- --- --- --- ---
-35 15.0 2549 1045 86 1985 986 95 --- --- --- --- --- ---
-30 10.7 3263 1143 87 2607 1092 96 1949 1034 105 1284 971 114
-25 14.0 4039 1241 88 3294 1199 97 2560 1147 106 1814 1089 115
-20 17.1 4920 1343 89 4085 1311 98 3275 1268 107 2435 1214 116
-15 19.3 5880 1448 91 4953 1426 99 4031 1391 108 3137 1345 117
-10 24.5 6921 1553 93 5893 1543 101 4881 1518 110 3850 1478 118
-5 28.8 8056 1660 95 6929 1662 103 5794 1647 111 4697 1617 119
0 33.5 9320 1764 97 8095 1781 105 6810 1778 113 5588 1758 121
5 36.5 10531 1870 98 9189 1901 106 7892 1910 114 6552 1901 122
10 43.7 11970 1969 100 10460 2018 108 9022 2041 116 7609 2044 124
25.0 33.5 19.5 14.7 7/8” S 3/8” S 16.46 lbs 1600 38.5 200
Dimensions, inches Line Connection* Pumpdown Air Oil Ch Gr. Wt.
L W H CH Suction Liquid
80F 90F 100F 110F
Return gas temp. 40F. 5F sub-cooling
90 F 90%
Ambient Temperatures
SCFM Oz. Lbs.
60 Hz Performance