Tecumseh AVD5558EXT Performance Data Sheet

Performance Data Sheet
AVD5558EXT
General Information
Model AVD5558EXT Refrigerant R-22 Test Condition ARI Performance Test Voltage 230V 3~ 60HZ Return Gas 18.3°C (65°F) RETURN GAS Motor Type 3PH
Performance Information
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 18100 17600 Watts 2200 2210 Amps 9.37 9.41
Lb/h 234 237
Btu/h 20100 19200 18500 Watts 2370 2410 2440 Amps 9.52 9.66 9.70
Lb/h 259 256 258
Btu/h 22900 21600 20500 19500 Watts 2520 2600 2670 2720 Amps 9.69 9.91 10.1 10.1
Lb/h 293 286 283 282
Btu/h 26400 24700 23200 21800 20500 Watts 2670 2780 2880 2970 3020 Amps 9.87 10.2 10.4 10.6 10.6
Lb/h 335 325 318 313 306
Btu/h 30600 28400 26500 24800 23000 Watts 2800 2940 3080 3210 3300 Amps 10.1 10.5 10.8 11.0 11.2
Lb/h 386 372 361 353 343
Btu/h 35400 32800 30600 28400 26200 24000 21500 Watts 2920 3090 3270 3430 3560 3650 3690 Amps 10.3 10.7 11.1 11.5 11.7 11.9 11.9
Lb/h 443 426 413 401 388 372 351
Btu/h 40700 37800 35100 32600 30100 27400 24500 Watts 3020 3230 3440 3640 3810 3940 4020 Amps 10.5 11.0 11.5 11.9 12.3 12.5 12.6
Lb/h 507 487 471 456 441 422 398
Btu/h 46500 43300 40200 37300 34400 31400 28100 Watts 3120 3360 3600 3830 4040 4210 4330 Amps 10.7 11.3 11.9 12.4 12.8 13.2 13.4
Lb/h 576 554 536 519 501 479 452
Btu/h 52700 49100 45800 42500 39300 35900 32300
25
30
35
40
45
50
55
Watts 3210 3470 3740 4010 4250 4460 4620 Amps 10.9 11.5 12.2 12.8 13.3 13.8 14.1
Lb/h 649 626 606 587 566 543 514
Btu/h 59300 55400 51700 48100 44500 40800 36800 Watts 3280 3570 3870 4170 4450 4700 4900 Amps 11.0 11.8 12.5 13.2 13.8 14.4 14.8
Lb/h 727 702 680 659 638 612 582
Btu/h 66200 62000 58000 54100 50200 46100 41800 Watts 3340 3660 3990 4320 4630 4910 5150 Amps 11.2 12.0 12.8 13.6 14.3 14.9 15.5
Lb/h 806 780 758 736 713 687 655
Btu/h 73300 68800 64600 60300 56100 51700 47100 Watts 3400 3740 4100 4450 4800 5120 5390 Amps 11.4 12.2 13.1 13.9 14.7 15.4 16.1
Lb/h 888 862 838 816 792 765 732
Btu/h 80600 75900 71300 66800 62300 57600 52700 Watts 3440 3810 4190 4580 4950 5300 5610 Amps 11.5 12.4 13.3 14.2 15.1 15.9 16.6
Lb/h 971 944 921 898 874 846 813
Btu/h 88100 83100 78200 73500 68700 63700 58400 Watts 3470 3860 4270 4680 5090 5470 5810 Amps 11.6 12.6 13.5 14.5 15.4 16.3 17.2
Lb/h 1050 1030 1000 981 957 930 896
Btu/h 95600 90300 85300 80200 75100 69900 64400 Watts 3490 3900 4340 4770 5210 5620 6000 Amps 11.7 12.7 13.7 14.7 15.7 16.7 17.6
Lb/h 1140 1110 1090 1070 1040 1010 981
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 6.265226E+04 3.189940E+03 6.955295E+00 8.231707E+02 C2 1.358656E+03 -8.807376E+00 -3.540467E-02 1.468604E+01 C3 -8.324168E+02 -3.869712E+01 1.862772E-02 -1.328155E+01 C4 1.085357E+01 -4.563990E-02 8.634002E-04 9.283805E-02 C5 -6.768416E+00 2.553629E-01 2.097301E-04 -6.156794E-02 C6 6.218567E+00 5.836602E-01 4.727926E-04 1.196818E-01 C7 -7.997048E-02 1.739539E-04 -4.909835E-06 -1.142600E-03 C8 3.011946E-02 -2.344969E-03 -8.239544E-06 8.139265E-04 C9 -7.364848E-03 2.452057E-03 8.730112E-06 -6.581520E-05
C10 -1.843210E-02 -2.272016E-03 -3.127889E-06 -3.740205E-04
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature
Loading...