Tecumseh AVD5558EXH User Manual

Performance Data Sheet
AVD5558EXH
General Information
Model AVD5558EXH Refrigerant R22 Test Condition ARI Test Voltage 575V 3~ 60HZ Return Gas 18.3°C (65°F) RETURN GAS Motor Type 3PH
Performance Information
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140 150
Btu/h 18200 17500 Watts 2200 2230 Amps 3.74 3.76
Lb/h 235 235
Btu/h 20100 19100 18400 Watts 2360 2430 2470 Amps 3.80 3.86 3.87
Lb/h 258 254 256
Btu/h 22800 21400 20300 19400 Watts 2510 2610 2690 2730 Amps 3.87 3.96 4.02 4.03
Lb/h 291 283 281 280
Btu/h 26200 24400 23000 21700 20500 Watts 2650 2790 2900 2980 3030 Amps 3.94 4.07 4.16 4.22 4.23
Lb/h 333 321 315 311 306
Btu/h 30300 28100 26300 24600 23000 Watts 2770 2950 3100 3220 3300 Amps 4.02 4.18 4.31 4.40 4.46
Lb/h 382 367 358 351 343
Btu/h 35000 32400 30200 28200 26200 24100 21600 Watts 2890 3100 3280 3440 3560 3650 3690 Amps 4.10 4.29 4.45 4.59 4.69 4.74 4.74
Lb/h 439 421 409 399 388 373 351
Btu/h 40200 37300 34800 32400 30000 27500 24600 Watts 2990 3230 3450 3650 3810 3930 4010 Amps 4.18 4.39 4.59 4.77 4.90 5.00 5.05
Lb/h 501 481 466 454 440 423 399
Btu/h 46000 42700 39800 37100 34400 31500 28300 24500 Watts 3080 3360 3610 3840 4040 4200 4320 4390 Amps 4.26 4.50 4.73 4.94 5.12 5.26 5.35 5.39
Lb/h 570 547 530 515 500 480 454 417
Btu/h 52200 48600 45300 42200 39200 35900 32400 28300
25
30
35
40
45
50
55
Watts 3160 3470 3760 4020 4250 4450 4610 4730 Amps 4.33 4.61 4.87 5.11 5.32 5.50 5.64 5.72
Lb/h 643 618 599 583 565 544 516 477
Btu/h 58700 54800 51200 47800 44400 40800 36900 32500 Watts 3230 3570 3890 4190 4450 4690 4890 5040 Amps 4.41 4.71 4.99 5.27 5.52 5.73 5.91 6.05
Lb/h 720 694 673 655 636 613 583 543
Btu/h 65700 61400 57500 53800 50000 46100 41900 37100 Watts 3280 3650 4010 4340 4640 4910 5140 5330 Amps 4.48 4.80 5.11 5.42 5.70 5.95 6.17 6.35
Lb/h 800 773 751 731 711 687 656 615
Btu/h 72900 68300 64100 60000 56000 51700 47200 42100 Watts 3320 3720 4110 4470 4810 5110 5380 5610 Amps 4.54 4.88 5.22 5.56 5.87 6.16 6.42 6.64
Lb/h 883 855 832 811 790 765 733 691
Btu/h 80300 75400 70900 66500 62100 57600 52700 47300 Watts 3350 3780 4200 4590 4960 5300 5610 5870 Amps 4.60 4.96 5.32 5.68 6.03 6.35 6.65 6.91
Lb/h 967 938 915 894 872 846 814 771
Btu/h 87900 82700 77900 73200 68500 63700 58500 52800 Watts 3370 3830 4270 4700 5100 5470 5810 6110 Amps 4.64 5.02 5.41 5.79 6.17 6.52 6.85 7.15
Lb/h 1050 1020 999 978 956 930 897 854
Btu/h 95600 90100 85000 80000 75100 69900 64500 58400 Watts 3370 3860 4330 4780 5220 5620 6000 6330 Amps 4.68 5.08 5.48 5.89 6.29 6.68 7.04 7.38
Lb/h 1140 1110 1080 1060 1040 1020 982 940
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 7.452179E+04 1.150928E+03 2.777743E+00 9.940446E+02 C2 1.343965E+03 -2.122395E+01 -1.413960E-02 1.464041E+01 C3 -1.186581E+03 1.683456E+01 7.439373E-03 -1.834656E+01 C4 1.183702E+01 -8.879316E-02 3.448171E-04 1.064533E-01 C5 -7.225120E+00 4.869070E-01 8.376013E-05 -7.040020E-02 C6 9.589470E+00 8.898856E-02 1.888197E-04 1.677220E-01 C7 -7.273916E-02 -3.347637E-04 -1.960846E-06 -1.042221E-03 C8 1.778752E-02 -1.606108E-03 -3.290635E-06 6.421476E-04 C9 -2.222656E-03 1.324608E-03 3.486554E-06 1.575141E-05
C10 -2.880001E-02 -8.242605E-04 -1.249188E-06 -5.215435E-04
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature
Loading...