AVD5545EXT
General Information
Model AVD5545EXT Refrigerant R-22 Test Condition ARI Performance Test Voltage 230V 3~ 60HZ Return Gas 18.3°C (65°F) RETURN GAS Motor Type 3PH
Performance Information
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 12800 10800 Watts 1590 1660 Amps 6.21 6.22
Lb/h 166 146
Btu/h 15700 13600 11600 Watts 1770 1840 1890 Amps 6.50 6.57 6.59
Lb/h 202 181 163
Btu/h 18800 16500 14400 12500 Watts 1930 2010 2080 2120 Amps 6.77 6.90 6.98 7.00
Lb/h 239 218 199 181
Btu/h 22000 19600 17300 15300 13400 Watts 2080 2180 2260 2310 2340 Amps 7.02 7.20 7.35 7.44 7.46
Lb/h 279 257 238 219 201
Btu/h 25500 22900 20500 18300 16200 Watts 2220 2340 2430 2500 2540 Amps 7.25 7.49 7.70 7.86 7.95
Lb/h 321 299 279 259 241
Btu/h 29300 26500 23900 21500 19200 17000 15000 Watts 2340 2480 2590 2680 2750 2780 2770 Amps 7.46 7.75 8.02 8.25 8.42 8.50 8.46
Lb/h 367 344 323 303 283 263 243
Btu/h 33400 30400 27600 25000 22500 20100 17700 Watts 2450 2600 2740 2850 2940 3000 3010 Amps 7.65 7.99 8.32 8.62 8.86 9.02 9.07
Lb/h 415 392 370 349 328 307 286
Btu/h 37900 34700 31600 28700 26000 23300 20800 Watts 2520 2710 2870 3010 3130 3210 3250 Amps 7.81 8.20 8.59 8.96 9.27 9.51 9.65
Lb/h 467 443 421 399 377 355 332
Btu/h 42700 39200 36000 32800 29800 26900 24100
25
30
35
40
45
50
55
Watts 2580 2790 2980 3160 3300 3410 3490 Amps 7.95 8.39 8.84 9.27 9.65 9.97 10.2
Lb/h 523 499 475 453 430 407 383
Btu/h 47900 44200 40700 37300 34000 30800 27700 Watts 2600 2850 3070 3280 3460 3600 3710 Amps 8.07 8.56 9.06 9.55 10.0 10.4 10.7
Lb/h 583 558 534 510 487 462 437
Btu/h 53500 49600 45800 42100 38600 35100 31700 Watts 2600 2880 3140 3380 3600 3780 3930 Amps 8.16 8.70 9.25 9.80 10.3 10.8 11.2
Lb/h 648 622 598 573 548 523 496
Btu/h 59600 55400 51300 47400 43500 39700 36000 Watts 2560 2880 3180 3460 3720 3940 4130 Amps 8.23 8.81 9.42 10.0 10.6 11.2 11.6
Lb/h 717 691 666 640 615 588 560
Btu/h 66200 61700 57300 53100 48900 44800 40700 Watts 2480 2850 3190 3520 3810 4080 4310 Amps 8.27 8.90 9.56 10.2 10.9 11.5 12.1
Lb/h 792 765 739 713 686 658 629
Btu/h 73300 68500 63800 59300 54800 50300 45900 Watts 2370 2780 3170 3540 3890 4200 4470 Amps 8.29 8.95 9.66 10.4 11.1 11.8 12.4
Lb/h 872 845 818 791 763 734 703
Btu/h 80900 75800 70800 65900 61100 56300 51500 Watts 2220 2670 3110 3530 3930 4290 4610 Amps 8.28 8.98 9.74 10.5 11.3 12.1 12.8
Lb/h 959 931 903 875 846 816 784
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 5.191173E+04 1.320958E+03 7.136907E+00 5.736272E+02 C2 8.683663E+02 5.904023E+00 1.363852E-02 7.984029E+00 C3 -5.152640E+02 3.312407E+00 -4.672028E-02 -5.611377E+00 C4 7.291879E+00 -8.078035E-01 -1.884353E-04 5.173236E-02 C5 -1.654008E+00 2.810276E-01 -1.666111E-04 1.492630E-02 C6 2.075257E+00 1.477475E-01 8.740430E-04 3.049884E-02 C7 4.017551E-02 -3.556198E-03 -8.997546E-07 4.457683E-04 C8 -2.926361E-02 6.437799E-03 -2.781369E-06 -1.012556E-05 C9 -9.184101E-03 1.364458E-04 7.481497E-06 -1.513984E-04
C10 -3.795487E-03 -8.724868E-04 -3.854150E-06 -7.990594E-05
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3