Performance Data Sheet
AVD5545EXG
General Information
Model AVD5545EXG Refrigerant R-22
Test Condition ARI Performance Test Voltage 460V 3~ 60HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type 3PH
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 12800 10800
Watts 1580 1650
Amps 3.13 3.18
Lb/h 166 144
Btu/h 15700 13500 11600
Watts 1760 1830 1890
Amps 3.27 3.32 3.37
Lb/h 201 179 160
Btu/h 18700 16400 14300 12500
Watts 1930 2010 2070 2110
Amps 3.41 3.48 3.53 3.57
Lb/h 239 216 197 179
Btu/h 22000 19500 17300 15300 13400
Watts 2080 2170 2250 2300 2330
Amps 3.55 3.63 3.71 3.76 3.79
Lb/h 278 255 235 217 200
Btu/h 25500 22900 20500 18300 16200
Watts 2220 2330 2420 2490 2540
Amps 3.69 3.79 3.88 3.95 4.01
Lb/h 321 297 276 257 239
Btu/h 29300 26500 23900 21500 19200 17000 14900
Watts 2340 2470 2580 2670 2740 2770 2760
Amps 3.82 3.94 4.05 4.14 4.22 4.28 4.30
Lb/h 366 342 321 301 281 262 243
Btu/h 33400 30400 27600 25000 22500 20100 17700
Watts 2440 2590 2730 2840 2930 2980 3000
Amps 3.95 4.08 4.21 4.33 4.44 4.52 4.57
Lb/h 414 390 368 347 327 307 286
Btu/h 37800 34600 31600 28700 26000 23400 20800
Watts 2520 2700 2860 3000 3110 3200 3240
Amps 4.06 4.21 4.37 4.51 4.65 4.76 4.84
Lb/h 466 442 419 397 376 355 332

Btu/h 42600 39200 35900 32800 29800 26900 24100
25
30
35
40
45
50
55
Watts 2570 2780 2970 3140 3280 3400 3470
Amps 4.15 4.33 4.51 4.69 4.85 4.99 5.11
Lb/h 522 497 474 451 429 407 383
Btu/h 47800 44100 40600 37300 34000 30900 27700
Watts 2590 2840 3060 3260 3440 3590 3700
Amps 4.23 4.43 4.64 4.84 5.04 5.22 5.38
Lb/h 582 557 532 509 486 463 438
Btu/h 53400 49500 45700 42100 38600 35100 31700
Watts 2590 2870 3130 3370 3580 3760 3910
Amps 4.28 4.51 4.75 4.98 5.21 5.43 5.63
Lb/h 647 621 596 572 548 523 497
Btu/h 59500 55300 51200 47300 43500 39800 36000
Watts 2550 2870 3170 3450 3700 3920 4110
Amps 4.30 4.56 4.83 5.10 5.37 5.62 5.86
Lb/h 716 689 664 639 614 588 560
Btu/h 66100 61500 57200 53000 48900 44800 40700
Watts 2470 2840 3180 3500 3800 4060 4290
Amps 4.30 4.59 4.89 5.20 5.50 5.80 6.08
Lb/h 790 763 737 711 685 658 629
Btu/h 73100 68300 63700 59100 54700 50300 45900
Watts 2360 2770 3160 3530 3870 4180 4450
Amps 4.26 4.59 4.92 5.27 5.61 5.95 6.28
Lb/h 870 842 816 789 762 734 703
Btu/h 80700 75600 70600 65800 61000 56200 51500
Watts 2210 2670 3100 3520 3910 4270 4600
Amps 4.19 4.55 4.92 5.31 5.70 6.08 6.45
Lb/h 955 927 900 872 844 815 783
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 5.563876E+04 1.152764E+03 3.166190E+00 6.486105E+02
C2 8.723966E+02 5.804851E+00 2.282667E-02 7.715661E+00
C3 -6.239023E+02 8.255713E+00 -5.416381E-03 -7.621347E+00
C4 7.291644E+00 -8.213973E-01 -3.892719E-04 5.363495E-02
C5 -1.792696E+00 2.869813E-01 -1.192306E-04 1.920074E-02
C6 3.103296E+00 9.841628E-02 2.061100E-04 4.755867E-02
C7 3.917898E-02 -3.420143E-03 -4.433278E-06 4.066208E-04
C8 -2.923776E-02 6.519336E-03 4.088112E-06 -1.247677E-05
C9 -8.215018E-03 6.866724E-05 2.357242E-06 -1.663555E-04
C10 -6.981854E-03 -7.113099E-04 -9.793538E-07 -1.268876E-04
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature