Tecumseh AVC5546EXN Performance Data Sheet

Performance Data Sheet
AVC5546EXN
General Information
Model AVC5546EXN Refrigerant R-22 Test Condition ASHRAE Performance Test Voltage 230V ~ 60HZ Return Gas -6.7°C (20°F) SUPERHEAT Motor Type PSC
Performance Information
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 14200 13200 Watts 1760 1800 Amps 8.43 7.78
Lb/h 184 175
Btu/h 15600 14600 12900 Watts 1960 2020 2030 Amps 9.44 8.91 8.68
Lb/h 201 193 177
Btu/h 17500 16500 14800 12600 Watts 2140 2230 2270 2260 Amps 10.3 9.93 9.81 9.82
Lb/h 225 218 203 180
Btu/h 20100 18900 17200 15000 12400 Watts 2290 2410 2490 2520 2490 Amps 11.1 10.8 10.9 11.0 11.0
Lb/h 256 249 235 213 186
Btu/h 23200 21900 20100 17800 15200 Watts 2430 2580 2690 2750 2760 Amps 11.8 11.7 11.8 12.0 12.2
Lb/h 293 287 273 252 225
Btu/h 26900 25500 23400 21000 18300 15500 12700 Watts 2550 2730 2870 2970 3010 3000 2930 Amps 12.3 12.4 12.6 13.0 13.3 13.4 13.1
Lb/h 338 331 316 296 269 239 207
Btu/h 31200 29500 27300 24700 21800 18800 16000 Watts 2640 2860 3030 3160 3250 3280 3260 Amps 12.8 13.0 13.4 13.9 14.4 14.6 14.3
Lb/h 389 381 366 345 319 289 257
Btu/h 36000 34100 31600 28800 25700 22600 19500 Watts 2720 2960 3170 3340 3470 3540 3560 Amps 13.1 13.5 14.1 14.8 15.3 15.7 15.6
Lb/h 447 438 421 400 373 343 311
Btu/h 41500 39200 36500 33300 30000 26600 23400
25
30
35
40
45
50
55
Watts 2780 3050 3300 3510 3670 3790 3850 Amps 13.3 13.9 14.7 15.5 16.2 16.7 16.7
Lb/h 511 500 482 459 432 402 370
Btu/h 47500 44900 41800 38300 34700 31000 27500 Watts 2810 3120 3410 3650 3860 4020 4120 Amps 13.4 14.2 15.2 16.2 17.1 17.7 17.9
Lb/h 581 568 549 525 496 465 432
Btu/h 54100 51100 47500 43700 39700 35700 31900 Watts 2830 3180 3490 3780 4020 4230 4380 Amps 13.4 14.4 15.6 16.8 17.9 18.7 19.0
Lb/h 658 642 621 595 565 532 498
Btu/h 61300 57800 53800 49500 45200 40800 36600 Watts 2830 3210 3560 3890 4170 4420 4620 Amps 13.3 14.5 15.9 17.3 18.6 19.6 20.0
Lb/h 740 722 698 670 638 603 568
Btu/h 69000 65000 60500 55800 51000 46200 41600 Watts 2800 3220 3610 3980 4310 4600 4850 Amps 13.1 14.5 16.2 17.8 19.3 20.4 21.1
Lb/h 829 808 781 750 715 679 642
Btu/h 77300 72700 67800 62500 57200 51900 46900 Watts 2760 3210 3650 4050 4420 4760 5060 Amps 12.7 14.5 16.3 18.2 19.9 21.2 22.1
Lb/h 924 899 869 834 797 758 719
Btu/h 86200 81000 75400 69600 63800 58000 52500 Watts 2700 3190 3660 4110 4520 4910 5250 Amps 12.3 14.3 16.4 18.5 20.4 22.0 23.0
Lb/h 1020 996 962 924 883 842 800
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 -1.368167E+04 3.629486E+02 4.222601E+01 -1.319548E+02 C2 8.980182E+02 -1.371321E+00 -1.728045E-01 8.688060E+00 C3 1.093903E+03 2.861134E+01 -9.021251E-01 1.117516E+01 C4 1.923932E+01 -5.072023E-01 -4.149593E-03 1.997351E-01 C5 -5.900347E+00 1.947332E-01 4.962115E-03 -4.551063E-02 C6 -1.059743E+01 1.376474E-02 8.543858E-03 -9.522836E-02 C7 -1.584769E-03 2.584042E-05 1.914693E-06 -1.149976E-04 C8 -9.491867E-02 1.337284E-03 2.275356E-05 -8.016745E-04 C9 2.199389E-02 2.362899E-03 -1.251136E-05 2.854267E-04
C10 2.745693E-02 -8.724720E-04 -2.659975E-05 2.014462E-04
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature