Tecumseh AVC5542EXN Performance Data Sheet

Performance Data Sheet
AVC5542EXN
General Information
Model AVC5542EXN Refrigerant R-22 Test Condition ASHRAE Performance Test Voltage 230V ~ 60HZ Return Gas -6.7°C (20°F) SUPERHEAT Motor Type PSC
Performance Information
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 13000 12100 Watts 1590 1630 Amps 7.26 7.39
Lb/h 168 160
Btu/h 14200 13300 11800 Watts 1760 1830 1840 Amps 7.91 8.20 8.22
Lb/h 183 177 162
Btu/h 16000 15100 13500 11500 Watts 1920 2010 2050 2040 Amps 8.49 8.94 9.12 9.06
Lb/h 205 199 186 165
Btu/h 18300 17300 15700 13700 11400 Watts 2050 2170 2240 2270 2240 Amps 9.01 9.62 9.95 10.0 9.94
Lb/h 234 228 215 195 170
Btu/h 21200 20100 18400 16200 13900 Watts 2170 2320 2420 2480 2480 Amps 9.47 10.2 10.7 11.0 11.0
Lb/h 268 263 249 230 206
Btu/h 24600 23300 21400 19200 16700 14200 11600 Watts 2270 2450 2580 2670 2710 2700 2640 Amps 9.86 10.8 11.4 11.8 12.0 12.0 11.9
Lb/h 309 303 290 270 247 219 189
Btu/h 28500 27000 25000 22600 19900 17200 14600 Watts 2350 2560 2730 2850 2920 2950 2940 Amps 10.2 11.3 12.1 12.6 13.0 13.1 13.1
Lb/h 356 349 335 316 292 264 235
Btu/h 33000 31200 28900 26300 23500 20600 17900 Watts 2420 2660 2860 3010 3120 3190 3210 Amps 10.4 11.7 12.6 13.3 13.8 14.2 14.3
Lb/h 408 400 386 366 341 314 285
Btu/h 37900 35900 33400 30500 27400 24300 21400
25
30
35
40
45
50
55
Watts 2470 2740 2970 3160 3300 3410 3470 Amps 10.6 12.0 13.1 14.0 14.6 15.1 15.4
Lb/h 467 457 441 420 395 368 338
Btu/h 43500 41100 38200 35000 31700 28400 25200 Watts 2500 2800 3060 3290 3470 3620 3720 Amps 10.8 12.3 13.6 14.6 15.4 16.0 16.5
Lb/h 531 520 502 480 454 425 395
Btu/h 49500 46700 43500 40000 36300 32700 29200 Watts 2520 2850 3140 3400 3620 3810 3950 Amps 10.8 12.5 14.0 15.1 16.1 16.8 17.5
Lb/h 601 588 568 544 517 487 456
Btu/h 56000 52800 49200 45300 41300 37300 33500 Watts 2520 2880 3200 3500 3760 3980 4170 Amps 10.9 12.7 14.3 15.6 16.7 17.6 18.4
Lb/h 677 661 639 613 583 552 520
Btu/h 63100 59500 55400 51100 46600 42300 38100 Watts 2500 2890 3250 3580 3880 4140 4370 Amps 10.8 12.8 14.5 16.0 17.2 18.3 19.2
Lb/h 758 739 714 686 654 621 587
Btu/h 70700 66500 62000 57200 52300 47500 42900 Watts 2460 2890 3280 3650 3980 4280 4560 Amps 10.7 12.8 14.7 16.3 17.7 18.9 20.0
Lb/h 845 822 795 763 729 694 658
Btu/h 78800 74100 69000 63700 58300 53100 48000 Watts 2410 2860 3290 3700 4070 4410 4730 Amps 10.5 12.8 14.8 16.6 18.1 19.5 20.7
Lb/h 937 911 880 845 808 770 732
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 -1.284283E+04 -6.556392E+02 -9.477338E+00 -1.260622E+02 C2 8.210148E+02 -5.069994E+00 -1.641412E-01 7.942445E+00 C3 1.009191E+03 5.222568E+01 4.215453E-01 1.036173E+01 C4 1.757948E+01 -4.053640E-01 -1.238561E-03 1.824974E-01 C5 -5.382771E+00 2.137241E-01 3.387620E-03 -4.148929E-02 C6 -9.766835E+00 -2.209578E-01 -2.811701E-03 -8.829374E-02 C7 -1.459330E-03 4.604753E-05 -2.078612E-08 -1.053033E-04 C8 -8.666347E-02 7.401355E-04 -6.041758E-07 -7.316136E-04 C9 2.004069E-02 2.086834E-03 -1.464811E-06 2.604302E-04
C10 2.532037E-02 -1.123626E-04 5.391894E-06 1.875793E-04
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3