Tecumseh AVB5542EXG Performance Data Sheet

Performance Data Sheet
AVB5542EXG
General Information
Model AVB5542EXG Refrigerant R-22 Test Condition ARI Performance Test Voltage 460V 3~ 60HZ Return Gas 18.3°C (65°F) RETURN GAS Motor Type 3PH
Performance Information
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 11100 10000 Watts 1620 1640 Amps 3.07 3.13
Lb/h 142 135
Btu/h 13600 12400 11100 Watts 1780 1810 1860 Amps 3.21 3.29 3.33
Lb/h 174 166 155
Btu/h 16400 15000 13500 11900 Watts 1930 1970 2030 2110 Amps 3.35 3.45 3.52 3.54
Lb/h 208 199 187 172
Btu/h 19400 17900 16200 14400 12400 Watts 2060 2120 2190 2280 2370 Amps 3.47 3.59 3.69 3.75 3.76
Lb/h 245 235 222 206 186
Btu/h 22700 21000 19100 17100 15000 Watts 2180 2250 2340 2450 2550 Amps 3.59 3.73 3.85 3.95 3.99
Lb/h 285 274 260 243 223
Btu/h 26400 24400 22300 20100 17800 15300 12500 Watts 2290 2370 2480 2600 2720 2820 2880 Amps 3.69 3.86 4.01 4.13 4.22 4.25 4.22
Lb/h 329 316 301 284 262 237 205
Btu/h 30300 28100 25800 23400 20900 18200 15300 Watts 2370 2480 2610 2750 2890 3000 3080 Amps 3.77 3.97 4.15 4.30 4.43 4.50 4.52
Lb/h 376 361 345 327 305 279 247
Btu/h 34700 32100 29500 26900 24200 21400 18300 Watts 2440 2570 2730 2890 3050 3180 3280 Amps 3.85 4.07 4.28 4.46 4.62 4.74 4.80
Lb/h 427 411 393 374 351 325 293
Btu/h 39300 36500 33600 30800 27800 24800 21600
25
30
35
40
45
50
55
Watts 2490 2650 2830 3010 3190 3350 3470 Amps 3.90 4.15 4.39 4.61 4.81 4.96 5.07
Lb/h 482 464 445 424 401 374 343
Btu/h 44400 41200 38100 34900 31800 28500 25100 Watts 2520 2710 2910 3130 3330 3520 3660 Amps 3.94 4.21 4.48 4.74 4.97 5.17 5.33
Lb/h 542 521 500 478 454 427 395
Btu/h 49900 46400 42900 39500 36000 32500 28900 Watts 2530 2740 2980 3220 3460 3670 3850 Amps 3.96 4.26 4.56 4.85 5.12 5.37 5.57
Lb/h 605 583 560 537 512 484 452
Btu/h 55900 51900 48100 44400 40600 36800 32900 Watts 2520 2760 3030 3310 3570 3820 4020 Amps 3.95 4.28 4.61 4.94 5.26 5.54 5.79
Lb/h 674 649 624 600 573 545 512
Btu/h 62300 57900 53800 49600 45600 41500 37400 Watts 2480 2760 3060 3370 3670 3950 4190 Amps 3.93 4.28 4.65 5.01 5.37 5.70 6.00
Lb/h 747 720 693 667 639 610 577
Btu/h 69200 64400 59800 55400 50900 46500 42100 Watts 2420 2740 3080 3420 3760 4070 4340 Amps 3.88 4.26 4.66 5.06 5.46 5.84 6.18
Lb/h 825 795 767 739 710 679 646
Btu/h 76600 71400 66400 61500 56700 52000 47300 Watts 2330 2690 3070 3450 3830 4180 4490 Amps 3.81 4.22 4.65 5.09 5.53 5.95 6.34
Lb/h 909 877 846 816 785 754 719
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 3.413166E+04 4.372269E+03 2.985368E+00 3.850306E+02 C2 1.159838E+03 -2.036472E+00 1.559166E-02 1.262859E+01 C3 -2.697560E+02 -7.708878E+01 -1.296407E-02 -3.731071E+00 C4 9.359489E+00 -6.781172E-01 -3.112363E-04 8.137098E-02 C5 -8.713340E+00 3.846262E-01 -2.204505E-04 -9.079520E-02 C6 1.744711E+00 8.025285E-01 3.907824E-04 3.981910E-02 C7 2.939279E-02 -1.475568E-03 -1.879404E-06 2.919079E-04 C8 -4.541964E-02 4.811631E-03 1.150735E-06 -2.344656E-04 C9 2.695278E-02 -5.233969E-04 4.039804E-06 3.720325E-04
C10 -8.393687E-03 -2.495609E-03 -1.907118E-06 -1.879530E-04
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature
Loading...