Performance Data Sheet
AVB5538EXN
General Information
Model AVB5538EXN Refrigerant R-22
Test Condition ARI Performance Test Voltage 230V ~ 60HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type PSC
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 10400 8320
Watts 1460 1470
Amps 6.52 6.63
Lb/h 134 111
Btu/h 12800 10700 8800
Watts 1600 1620 1620
Amps 7.10 7.28 7.31
Lb/h 165 143 122
Btu/h 15400 13300 11300 9430
Watts 1720 1770 1790 1780
Amps 7.63 7.89 8.01 7.98
Lb/h 197 176 156 136
Btu/h 18200 16000 14000 12000 10100
Watts 1840 1900 1940 1950 1940
Amps 8.11 8.46 8.67 8.73 8.64
Lb/h 231 211 191 172 151
Btu/h 21300 19000 16800 14700 12700
Watts 1940 2020 2080 2120 2130
Amps 8.55 8.98 9.29 9.45 9.46
Lb/h 268 248 228 209 189
Btu/h 24500 22100 19900 17700 15500 13300 11100
Watts 2030 2130 2210 2270 2310 2310 2280
Amps 8.93 9.45 9.86 10.1 10.3 10.2 10.0
Lb/h 307 287 268 249 228 206 181
Btu/h 28100 25600 23100 20800 18500 16100 13800
Watts 2110 2230 2340 2420 2480 2510 2510
Amps 9.25 9.87 10.4 10.8 11.0 11.1 11.0
Lb/h 349 329 310 291 270 247 222
Btu/h 32000 29300 26700 24200 21700 19100 16600
Watts 2170 2320 2450 2550 2640 2690 2720
Amps 9.51 10.2 10.8 11.3 11.7 11.9 12.0
Lb/h 394 375 355 335 314 291 265
Btu/h 36200 33300 30500 27800 25100 22400 19600
25
30
35
40
45
50
55
Watts 2220 2390 2540 2680 2790 2870 2930
Amps 9.71 10.5 11.3 11.9 12.4 12.7 12.9
Lb/h 443 423 403 383 362 338 311
Btu/h 40700 37600 34600 31700 28800 25800 22800
Watts 2250 2440 2630 2790 2930 3040 3130
Amps 9.84 10.8 11.6 12.4 13.0 13.5 13.8
Lb/h 496 475 455 434 412 388 360
Btu/h 45600 42300 39100 35900 32800 29600 26300
Watts 2260 2480 2690 2890 3060 3200 3320
Amps 9.90 10.9 11.9 12.8 13.5 14.2 14.7
Lb/h 553 532 511 489 466 441 412
Btu/h 51000 47400 44000 40500 37100 33600 30100
Watts 2250 2510 2750 2970 3170 3350 3490
Amps 9.89 11.1 12.1 13.1 14.0 14.8 15.5
Lb/h 614 592 570 548 524 498 468
Btu/h 56800 52900 49200 45500 41800 38000 34100
Watts 2230 2510 2780 3040 3270 3480 3660
Amps 9.80 11.1 12.3 13.4 14.5 15.4 16.2
Lb/h 680 657 635 611 586 558 527
Btu/h 63000 58900 54900 50800 46800 42700 38500
Watts 2180 2500 2800 3090 3360 3600 3820
Amps 9.64 11.0 12.4 13.7 14.8 15.9 16.9
Lb/h 751 727 704 679 652 623 591
Btu/h 69800 65300 61000 56600 52200 47800 43300
Watts 2120 2470 2800 3130 3430 3710 3960
Amps 9.39 10.9 12.4 13.8 15.2 16.4 17.5
Lb/h 827 803 778 752 724 693 659
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 4.589091E+04 1.025182E+03 1.946327E+00 5.292728E+02
C2 6.679982E+02 -3.353794E+00 6.665059E-03 5.675295E+00
C3 -5.093141E+02 9.834340E+00 9.982292E-02 -6.246661E+00
C4 8.021188E+00 -4.482387E-01 -1.681252E-03 7.059795E-02
C5 -5.573340E-01 2.543899E-01 4.861110E-04 2.495573E-02
C6 2.617571E+00 4.921201E-02 -1.175955E-04 4.297257E-02
C7 3.555497E-02 -1.159105E-03 -4.157302E-06 4.157729E-04
C8 -4.431539E-02 2.595809E-03 8.259016E-06 -3.138379E-04
C9 -6.302920E-03 7.544548E-04 7.234209E-06 -9.235857E-05
C10 -7.164312E-03 -5.627636E-04 -2.081043E-06 -1.431608E-04
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature