TECUMSEH HERMETIC
CONDENSING UNIT
Model AVA9522ZXTHN
BOM 32L3152-2E
Air Cooled 2 ¾ HP
Application Commercial Temp
AVA9522ZXTHN
TPC___REV 1
March 21, 2012
Refrigerant R404A
36.25
35.38
25.50 23.50
Model
A V A9 52 2ZX TH N
*) Enclosure Mounting Holes, 38.5 x 25.5
Factory charge 20 psig d ry air,
Evap orator
o
Psig BTUH Watts Head Cond T BTUH Watts Head C ond T BTUH Watts Head Cond T BTUH Watts Head Cond T
F
-10 23.2 10500 2460 211 90 9300 2450 256 104 8600 2440 273 109 7000 2400 308 118
-5 27.5 12100 263 0 217 92 10700 265 0 262 1 06 99 00 2650 279 1 10 830 0 2630 314 119
0 32.1 13800 2 800 2 23 94 12100 2850 26 9 1 07 113 00 2860 285 112 960 0 2860 321 121
5 37.0 15600 2 980 230 95 13700 305 0 275 109 128 00 30 70 292 113 1100 0 3080 327 122
10 42.4 17500 315 0 237 97 15300 3 250 283 110 144 00 3280 299 114 1250 0 3310 334 123
15 48.2 19500 333 0 245 99 17100 3 460 291 112 161 00 3490 307 116 1410 0 3540 342 125
20 54.5 21700 351 0 253 100 18900 3 66 0 299 113 179 00 3700 316 117 1580 0 3770 350 126
25 61.2 24000 370 0 263 102 20900 3 88 0 308 115 198 00 3930 325 119 1760 0 4010 359 128
30 68.4 26400 390 0 273 104 23100 4 10 0 319 117 218 00 4150 335 121 1950 0 4250 368 129
35 76.1 29000 411 0 284 106 25300 4 33 0 329 119 240 00 4390 345 123 2160 0 4510 378 131
40 84.4 31800 433 0 296 109 27700 4 57 0 341 121 263 00 4640 357 125 2380 0 4770 390 133
45 93.2 34700 457 0 309 111 30300 4 83 0 354 123 288 00 4910 370 127 2610 0 5050 402 135
50 103 .0 37800 4 820 323 114 33000 510 0 368 126 3 1400 51 80 384 129 2850 0 5340 415 137
55 113 .0 41100 5 090 339 117 35900 539 0 384 129 3 4200 54 80 399 132 3110 0 5650 430 140
Performance @ 60 H z ; Ret urn Gas Tem p erature 20
Dim. E nclosur e(inch)* Line con ne c tions Pum p d o w n Air flow O il Ch. Gross weigh t
LWH
31.50 40.50 26.75
MUST BE EVACUATED
o
F95
80
26.08
4.24
Suction Liquid
7/8 1/2 20.45
Ambient Temeratures
o
F100
o
F max superheat above 20oF evap, 40oF max below 20oF evap ; --- SubCooling 5oF
90% @ 90
o
F
SCFM Oz. Lbs.
1800 54 340
o
F110
o
F
PRELIMINARY PERFORMANCE DATA
AVA9522ZXTHN
TPC___REV 1
March 21, 2012
Parts/Specifications
STANDARD OPTIONAL
Unit BOM 32L3152-2
Unit MODEL A VA9522ZXTH N
Refrigeration RANGE -10°F to 45°F Fan Blade 51568 Defrost Clock (Tn option)
Design Pressure Low 181 Fan Guard 70831 Defrost Heaters Contactor
Design Pressure High 450 Shroud 70648-2 Rec. Heater (R option)
Volts - HZ - Ph 200-230V 3~ 60HZ Solenoid Valve (loose)
Voltage Range 180 - 254 High Pressure switch 84095-2L Disconnect (D option)
Min. Circuit Ampacity 21.24 Low Pre ssure Control 84026-2
Max. Fuse Size 35 Du al Pressu re Conrol Wi ri n g with F option WD23-2AT2
Compressor MODEL AV20 3RT-01 2-A2 Condenser 50858-1
Compressor BO M AVA9522ZXT He ad Master Valve 70083-1 Phase M onitor, ICM402 900-10026
Com
ressor LR
Compressor RL
74 Check Valve 56626
10.30 Process V alve 31583-1
OverLoad Suction Valve 56500-K14
Relay E Enclosure
Run Capacitor Receiver 51099-2L R Receiver Heater
Run Capacitor Rating Receiver Qty 1 A Adjustable fan control
Sta rt Capacitor Ac cumulator F Fixed fan Control
Sta rt Capacitor R a ting Liquid Filter 52000-084D T1 Defrost timer op tion
Contactor 910 14B Sight Glass 70084-2 T2 Defrost timer & Defrost Heate rs Contactor
Unit Drawin g DGU192 0 -L102 S Solenoid liquid Va lve (su pp lied loose)
Wiring D iagram WD2 3-2F M CrankC a se H ea ter 90699
Fan Motor 810F050C20 Fix.Fan Switch #1 (F opt.)84132-01
Fan Motor Qt
2 Fix .Fan S witch #2 (F opt.
Fan Motor RLA 0.7 Adjus. Fan Ctrl. (A opt.)
Wi ri n g with A option
BOM INDEX DESCRIPTION
Liquid Valve 56500-K08
32xY YYY- 2ER A (F)TnD S
Suction Filter 70822-5S D Disconnect
NOTES
FIELD WIRING NOTES
1. ALL FIELD WIRING MUST BE DONE IN C O M PLIANCE WITH ALL
APPLICAB L E LOCAL AND NATIONAL CO DES.
2. CONNECT INCOMING POW ER LE AD S FRO M POWER SUPPLY
TO L1, L2, AND L3 IN COMPRESSOR C ONTACTOR OR TO L1, L2 AND L3 IN
DISCONNECT SWITCH (IF PROVIDED ). USE CO O PE R CO N DU CT O RS
ONLY. (EMPLOYER DES CONDUCTEURS DE CUIVER SEULEMENT.)
PROVIDE EQUIPMEN T G RO U NDING CO NDUCTOR.
USE 75°C (M IN .) WIRING
GENERAL NOTES:
A. CONTACTOR COIL CIRCU IT IS FA CT O RY C O NNE CTE D TO 230 V S O URC E IN
PANEL AS SHOWN
B. COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR.
ALLOW TIME FOR RESET.
AFC
ADJUSTABLE FAN CONTROL
LP
LOW PRESSURE CONTROL
HP
HIGH PRESSURE SWITCH
D.T.
DISCHARGE THERMOSTAT
FACTORY COMPONENTS
OPTIONAL FACTORY COMPONENTS
CONDENSING UNIT WIRING, 230V 60Hz 3 Ph,
fixed fan contro l,
PHASE MONITOR OPTION
-
REVISION
WD23-2FM
AUG. 18, 2009
CONTACTOR COIL
POWER SUPPLY
230-60-3
COMPRESSOR
COMPRESSOR
see note A
L3L2T3
L1 T1
TERMINAL
IMPORTANT:
COMPRESSOR EQUIPPED W ITH AN INTERNA L OVERLOA D
PROTECTOR. ALLOW TIME FOR RESET.
USE COPPER CONDUCTORS ONLY.
(EMPLOYER DES CONDUCTEUERS DE CUIVER
SEULEMENT.)
FAN 1
FAN 2
TO "Y-OUT"
AT PHASE
HP LP
T2
GRD
S
CRANK CASE
HEATER
C
R
BLACK
RED
YELLOW
MONITOR
D.T.
TERMINAL
BOARD
T1L1T2
TO "230 VAC"
A
B
AT PHASE
MONITOR
TO "C"
C
AT PHASE
MONITOR
L1
P1
L2 L3 T3T1 F1 F2
L2
L3
T3
TO "P1"
AT TERMINAL
BOARD
Y Y-
A
OUT
ICM402
3 PHASE
MONITOR
L1 L2 L3
FFC
TO "L2"
AT TERMINAL
C
BOARD
C 115
VAC
TO "L1"
B
AT TERMINAL
BOARD
230
VAC