Performance Data Sheet
AVA5546EXC
General Information
Model AVA5546EXC Refrigerant R-22
Test Condition ASHRAE Performance Test Voltage 240V ~ 50HZ
Return Gas -6.7°C (20°F) SUPERHEAT Motor Type PSC
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 13800 11900
Watts 1490 1430
Amps 11.5 11.4
Lb/h 180 159
Btu/h 14500 12700 10800
Watts 1640 1630 1580
Amps 12.0 11.9 11.8
Lb/h 188 169 149
Btu/h 15600 13900 12200 10300
Watts 1780 1810 1800 1760
Amps 12.4 12.4 12.4 12.3
Lb/h 201 185 167 148
Btu/h 17300 15700 13900 12100 10300
Watts 1910 1970 2010 2000 1960
Amps 12.8 12.9 13.0 12.9 12.8
Lb/h 221 206 190 173 153
Btu/h 19600 17900 16100 14300 12400
Watts 2010 2120 2190 2230 2230
Amps 13.1 13.3 13.5 13.5 13.5
Lb/h 247 234 219 203 184
Btu/h 22300 20500 18700 16800 14800 12800 10600
Watts 2100 2250 2360 2430 2470 2470 2430
Amps 13.4 13.7 13.9 14.1 14.2 14.2 14.1
Lb/h 279 267 253 237 219 198 173
Btu/h 25500 23700 21800 19800 17700 15500 13200
Watts 2180 2360 2500 2610 2690 2730 2730
Amps 13.6 14.0 14.3 14.6 14.8 14.9 14.9
Lb/h 316 305 292 277 259 238 213
Btu/h 29200 27300 25300 23100 20800 18500 16000
Watts 2240 2450 2630 2780 2890 2970 3010
Amps 13.8 14.3 14.7 15.1 15.4 15.6 15.7
Lb/h 360 349 336 321 303 282 256
Btu/h 33500 31400 29200 26800 24400 21800 19100
25
30
35
40
45
50
55
Watts 2280 2530 2740 2930 3070 3190 3260
Amps 13.9 14.5 15.0 15.5 15.9 16.2 16.5
Lb/h 410 399 386 370 352 330 303
Btu/h 38300 35900 33500 30900 28200 25400 22400
Watts 2310 2590 2840 3050 3240 3380 3490
Amps 14.0 14.7 15.3 15.9 16.4 16.8 17.2
Lb/h 465 454 440 424 405 381 354
Btu/h 43500 41000 38300 35400 32500 29300 26100
Watts 2330 2640 2920 3160 3380 3560 3700
Amps 14.0 14.8 15.5 16.2 16.8 17.4 17.9
Lb/h 526 514 500 482 462 437 408
Btu/h 49300 46500 43500 40300 37000 33600 29900
Watts 2330 2670 2980 3260 3500 3710 3890
Amps 14.0 14.9 15.7 16.5 17.2 17.9 18.5
Lb/h 592 580 564 545 523 496 466
Btu/h 55600 52400 49100 45600 41900 38100 34100
Watts 2320 2690 3030 3330 3610 3850 4060
Amps 13.9 14.9 15.8 16.7 17.6 18.4 19.1
Lb/h 665 650 633 613 588 560 526
Btu/h 62400 58900 55200 51300 47200 43000 38500
Watts 2300 2690 3060 3390 3700 3970 4200
Amps 13.8 14.9 15.9 16.9 17.9 18.8 19.7
Lb/h 743 727 707 685 658 627 591
Btu/h 69700 65800 61700 57300 52800 48100 43200
Watts 2260 2680 3080 3440 3770 4070 4330
Amps 13.6 14.8 16.0 17.1 18.2 19.2 20.2
Lb/h 826 808 786 761 731 697 658
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 2.859160E+04 3.521915E+02 8.681381E+00 3.483445E+02
C2 2.792734E+02 -3.631855E+01 -3.978521E-02 4.807895E-01
C3 -1.161428E+02 2.895406E+01 8.121095E-02 -2.244494E+00
C4 1.669418E+01 -1.288093E-01 -1.233448E-03 1.806726E-01
C5 2.324440E+00 7.028735E-01 1.021408E-03 6.569208E-02
C6 -3.051653E-01 -9.831744E-02 -3.546668E-04 1.420741E-02
C7 3.617681E-05 5.784858E-04 -7.531925E-07 -7.526316E-05
C8 -8.098580E-02 -2.525144E-03 3.518505E-06 -7.416505E-04
C9 -1.167483E-02 4.718783E-04 4.290451E-06 -1.847507E-04
C10 -5.375662E-06 -2.585911E-04 -2.970443E-07 -7.560356E-05
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature