Performance Data Sheet
AVA5542WXT
General Information
Model AVA5542WXT Refrigerant R407C/R22
Test Condition ARI (R407C) Test Voltage 230V 3~ 60HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type 3PH
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140 150
Btu/h 18300 18200
Watts 1330 1260
Amps 5.04 5.72
Lb/h 134 112
Btu/h 16800 16100 15900
Watts 1580 1490 1490
Amps 5.33 6.05 6.39
Lb/h 163 132 123
Btu/h 16500 15200 14600 14100
Watts 1820 1720 1710 1740
Amps 5.63 6.39 6.78 6.86
Lb/h 197 158 142 138
Btu/h 17500 15400 14300 13500 12500
Watts 2050 1930 1920 1960 1980
Amps 5.93 6.73 7.17 7.33 7.24
Lb/h 237 189 167 158 153
Btu/h 19600 16800 15100 13900 12700
Watts 2270 2140 2120 2170 2210
Amps 6.24 7.06 7.56 7.78 7.78
Lb/h 283 226 197 184 176
Btu/h 22900 19200 16800 15100 13700 11900 9190
Watts 2490 2340 2320 2370 2430 2440 2330
Amps 6.55 7.40 7.94 8.23 8.32 8.25 8.09
Lb/h 335 270 233 215 203 189 159
Btu/h 27200 22500 19400 17200 15400 13500 10900
Watts 2700 2530 2500 2560 2640 2680 2610
Amps 6.87 7.74 8.32 8.67 8.84 8.88 8.83
Lb/h 395 320 276 252 237 221 193
Btu/h 32500 26800 22800 20000 17800 15700 13100 9430
Watts 2910 2710 2680 2740 2840 2900 2880 2700
Amps 7.20 8.08 8.70 9.10 9.35 9.48 9.56 9.62
Lb/h 463 378 326 296 278 260 232 182
Btu/h 38800 31900 27000 23500 20800 18400 15700 12200
25
30
35
40
45
50
55
Watts 3110 2890 2850 2920 3030 3120 3140 3010
Amps 7.53 8.42 9.07 9.53 9.84 10.1 10.3 10.5
Lb/h 538 443 383 347 325 305 277 230
Btu/h 45900 37900 32000 27700 24400 21600 18800 15300
Watts 3300 3070 3020 3080 3210 3330 3390 3310
Amps 7.87 8.76 9.44 9.94 10.3 10.6 10.9 11.3
Lb/h 621 516 448 406 379 357 329 283
Btu/h 53900 44500 37600 32400 28500 25200 22200 18700
Watts 3500 3240 3180 3240 3390 3530 3630 3600
Amps 8.21 9.11 9.80 10.3 10.8 11.2 11.6 12.0
Lb/h 714 598 521 472 441 416 388 344
Btu/h 62600 51900 43700 37600 33000 29200 25800 22200
Watts 3690 3400 3330 3400 3550 3730 3860 3880
Amps 8.56 9.45 10.2 10.7 11.2 11.7 12.2 12.8
Lb/h 816 688 603 547 511 484 454 411
Btu/h 72000 59900 50500 43300 37800 33500 29700 25900
Watts 3870 3570 3480 3550 3720 3910 4080 4160
Amps 8.91 9.80 10.5 11.1 11.7 12.2 12.8 13.5
Lb/h 927 788 693 631 589 559 528 487
Btu/h 82100 68400 57700 49400 43100 38000 33700 29600
Watts 4060 3730 3630 3700 3870 4090 4300 4420
Amps 9.27 10.1 10.9 11.5 12.1 12.7 13.4 14.2
Lb/h 1050 898 794 724 677 643 611 570
Btu/h 92800 77500 65400 55900 48500 42700 37800 33400
Watts 4250 3890 3780 3840 4030 4270 4510 4680
Amps 9.64 10.5 11.2 11.9 12.5 13.2 14.0 14.9
Lb/h 1180 1020 904 826 774 736 703 662
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 1.319133E+05 1.440895E+04 -1.911167E+01 2.810066E+03
C2 3.041135E+03 1.597172E+02 1.610945E-01 3.739774E+01
C3 -3.187056E+03 -3.560281E+02 5.820824E-01 -6.955885E+01
C4 3.661615E+01 3.906383E-03 8.676646E-04 1.702279E-01
C5 -5.093189E+01 -2.405717E+00 -2.907395E-03 -5.235257E-01
C6 2.933243E+01 3.349891E+00 -4.048519E-03 6.118684E-01
C7 -7.897012E-02 9.639096E-04 -8.434423E-09 5.704305E-04
C8 -1.631041E-01 -1.959300E-03 -9.438817E-06 -5.714406E-04
C9 2.102199E-01 1.221907E-02 2.074026E-05 2.041224E-03
C10 -9.222370E-02 -1.038287E-02 8.563109E-06 -1.806040E-03
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature