Performance Data Sheet
AVA5542WXG
General Information
Model AVA5542WXG Refrigerant R407C/R22
Test Condition ARI (R407C) Test Voltage 460V 3~ 60HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type 3PH
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140 150
Btu/h 18400 18200
Watts 1360 1280
Amps 2.53 2.87
Lb/h 134 112
Btu/h 16800 16100 15900
Watts 1610 1520 1520
Amps 2.68 3.04 3.21
Lb/h 163 132 123
Btu/h 16500 15200 14600 14100
Watts 1850 1750 1740 1770
Amps 2.83 3.21 3.41 3.45
Lb/h 197 158 142 138
Btu/h 17500 15400 14300 13500 12500
Watts 2090 1970 1960 2000 2020
Amps 2.98 3.38 3.61 3.68 3.64
Lb/h 237 189 167 158 153
Btu/h 19600 16800 15100 13900 12700
Watts 2320 2180 2170 2210 2250
Amps 3.13 3.55 3.80 3.91 3.91
Lb/h 283 226 197 184 176
Btu/h 22900 19200 16800 15100 13700 11900 9190
Watts 2540 2380 2360 2410 2480 2490 2380
Amps 3.29 3.72 3.99 4.14 4.18 4.15 4.06
Lb/h 336 270 233 215 204 189 159
Btu/h 27200 22500 19400 17200 15400 13500 10900
Watts 2750 2580 2550 2610 2690 2730 2660
Amps 3.45 3.89 4.18 4.36 4.44 4.46 4.44
Lb/h 395 320 276 252 237 221 193
Btu/h 32500 26800 22800 20000 17800 15700 13100 9440
Watts 2960 2770 2730 2790 2890 2960 2940 2750
Amps 3.62 4.06 4.37 4.58 4.70 4.76 4.80 4.84
Lb/h 463 378 326 296 278 260 232 182
Btu/h 38800 31900 27000 23500 20800 18400 15700 12200
25
30
35
40
45
50
55
Watts 3170 2950 2910 2970 3090 3180 3200 3070
Amps 3.78 4.23 4.56 4.79 4.95 5.06 5.15 5.26
Lb/h 538 443 383 347 325 305 277 230
Btu/h 45900 37900 32000 27700 24400 21600 18800 15300
Watts 3370 3130 3070 3140 3270 3400 3450 3380
Amps 3.95 4.40 4.74 5.00 5.19 5.35 5.49 5.66
Lb/h 622 516 448 406 379 357 329 283
Btu/h 53900 44500 37600 32400 28500 25200 22200 18700
Watts 3560 3300 3240 3310 3450 3600 3700 3670
Amps 4.13 4.58 4.93 5.20 5.42 5.62 5.82 6.05
Lb/h 714 598 521 472 441 416 388 344
Btu/h 62600 51900 43800 37600 33000 29200 25800 22200
Watts 3760 3470 3390 3470 3620 3800 3930 3960
Amps 4.30 4.75 5.11 5.40 5.65 5.89 6.14 6.43
Lb/h 816 689 603 547 511 484 454 412
Btu/h 72000 59900 50500 43300 37900 33500 29700 25900
Watts 3950 3640 3550 3620 3790 3990 4160 4240
Amps 4.48 4.92 5.29 5.59 5.87 6.15 6.45 6.80
Lb/h 927 789 694 631 590 559 529 487
Btu/h 82100 68400 57700 49500 43100 38000 33700 29700
Watts 4140 3800 3700 3770 3950 4170 4380 4510
Amps 4.66 5.10 5.46 5.79 6.09 6.40 6.74 7.15
Lb/h 1050 899 794 724 677 643 611 570
Btu/h 92800 77500 65400 55900 48500 42700 37800 33400
Watts 4330 3970 3850 3920 4110 4350 4590 4770
Amps 4.84 5.27 5.64 5.97 6.30 6.64 7.03 7.48
Lb/h 1180 1020 904 826 774 736 703 662
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 1.319562E+05 1.468710E+04 -9.603992E+00 2.810762E+03
C2 3.042124E+03 1.628006E+02 8.095301E-02 3.740702E+01
C3 -3.188093E+03 -3.629008E+02 2.925079E-01 -6.957608E+01
C4 3.662810E+01 3.981505E-03 4.360156E-04 1.702703E-01
C5 -5.094846E+01 -2.452159E+00 -1.461019E-03 -5.236558E-01
C6 2.934197E+01 3.414557E+00 -2.034462E-03 6.120199E-01
C7 -7.899594E-02 9.825184E-04 -4.216026E-09 5.705711E-04
C8 -1.631573E-01 -1.997124E-03 -4.743184E-06 -5.715835E-04
C9 2.102883E-01 1.245496E-02 1.042237E-05 2.041731E-03
C10 -9.225370E-02 -1.058330E-02 4.303137E-06 -1.806488E-03
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature