Performance Data Sheet
AVA5542WXC
General Information
Model AVA5542WXC Refrigerant R407C/R22
Test Condition ASHRAE (R22) Test Voltage 240V ~ 50HZ
Return Gas -6.7°C (20°F) SUPERHEAT Motor Type PSC
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140 150
Btu/h 12600 10800
Watts 1410 1370
Amps 9.62 9.50
Lb/h 165 145
Btu/h 13200 11600 9890
Watts 1550 1540 1500
Amps 10.1 10.0 9.90
Lb/h 172 154 136
Btu/h 14300 12700 11100 9450
Watts 1670 1700 1690 1650
Amps 10.5 10.5 10.5 10.3
Lb/h 184 169 153 135
Btu/h 15800 14300 12700 11100 9360
Watts 1780 1840 1870 1870 1830
Amps 10.8 10.9 11.0 10.9 10.8
Lb/h 202 189 174 158 140
Btu/h 17900 16300 14700 13000 11300
Watts 1880 1970 2040 2070 2070
Amps 11.1 11.3 11.4 11.5 11.4
Lb/h 226 214 200 185 168
Btu/h 20300 18800 17100 15400 13600 11700 9710
Watts 1960 2090 2190 2250 2290 2290 2270
Amps 11.3 11.6 11.8 12.0 12.0 12.0 11.9
Lb/h 255 244 231 217 200 181 159
Btu/h 23300 21600 19900 18100 16100 14100 12000
Watts 2040 2190 2320 2420 2490 2530 2540
Amps 11.5 11.9 12.2 12.4 12.6 12.6 12.7
Lb/h 290 279 267 253 236 217 195
Btu/h 26700 24900 23100 21100 19000 16900 14600 12300
Watts 2090 2280 2440 2570 2670 2750 2790 2820
Amps 11.7 12.1 12.5 12.8 13.1 13.2 13.4 13.4
Lb/h 329 319 307 293 277 257 234 208
Btu/h 30600 28700 26600 24500 22300 19900 17400 14900
25
30
35
40
45
50
55
Watts 2140 2360 2550 2710 2840 2950 3030 3090
Amps 11.8 12.3 12.8 13.2 13.5 13.8 14.0 14.1
Lb/h 375 365 352 338 321 301 277 250
Btu/h 34900 32800 30600 28300 25800 23200 20500 17700
Watts 2170 2420 2640 2830 2990 3130 3240 3330
Amps 11.8 12.5 13.0 13.5 13.9 14.3 14.6 14.9
Lb/h 425 415 402 387 369 348 323 295
Btu/h 39800 37400 35000 32400 29600 26800 23800 20700
Watts 2190 2470 2710 2930 3130 3300 3440 3560
Amps 11.8 12.5 13.2 13.8 14.3 14.8 15.2 15.5
Lb/h 481 470 457 441 422 399 373 342
Btu/h 45000 42400 39700 36800 33800 30700 27300 23900
Watts 2190 2500 2770 3020 3250 3440 3620 3770
Amps 11.8 12.6 13.3 14.0 14.6 15.2 15.7 16.2
Lb/h 542 530 516 498 478 453 425 393
Btu/h 50800 47900 44900 41700 38300 34800 31100 27300
Watts 2190 2520 2820 3100 3350 3580 3780 3960
Amps 11.7 12.6 13.4 14.2 14.9 15.6 16.2 16.8
Lb/h 608 595 579 560 537 511 481 446
Btu/h 57000 53800 50400 46800 43100 39200 35200 31000
Watts 2160 2520 2850 3150 3430 3690 3920 4130
Amps 11.6 12.6 13.5 14.4 15.2 16.0 16.7 17.3
Lb/h 679 664 646 625 601 573 540 502
Btu/h 63700 60100 56300 52400 48200 43900 39500 34800
Watts 2130 2510 2860 3190 3500 3780 4040 4280
Amps 11.4 12.5 13.5 14.5 15.4 16.3 17.1 17.9
Lb/h 755 738 718 695 668 637 601 561
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 2.614990E+04 -2.191207E+01 7.452362E+00 3.197310E+02
C2 2.546537E+02 -2.854815E+01 -4.668723E-02 4.767726E-01
C3 -1.064635E+02 3.847919E+01 6.774729E-02 -2.023071E+00
C4 1.524597E+01 -1.242715E-01 -1.249946E-03 1.644772E-01
C5 2.132805E+00 5.677887E-01 1.217014E-03 6.000426E-02
C6 -2.802235E-01 -2.139120E-01 -3.105284E-04 1.206460E-02
C7 -6.931932E-06 -1.196451E-04 3.648962E-07 -7.921624E-05
C8 -7.391549E-02 -1.682062E-03 3.345611E-06 -6.626858E-04
C9 -1.072208E-02 6.255733E-04 2.051377E-06 -1.738212E-04
C10 1.354161E-05 1.831774E-04 -1.698229E-07 -6.419109E-05
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature