Tecumseh AVA5542EXN Performance Data Sheet

Performance Data Sheet
AVA5542EXN
General Information
Model AVA5542EXN Refrigerant R-22 Test Condition ASHRAE Performance Test Voltage 230V ~ 60HZ Return Gas 18.3°C (65°F) RETURN GAS Motor Type PSC
Performance Information
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 11400 10500 Watts 1830 1700 Amps 8.95 8.56
Lb/h 162 146
Btu/h 13600 12300 11000 Watts 2010 1900 1790 Amps 9.55 9.24 8.95
Lb/h 186 168 150
Btu/h 16200 14500 12900 11300 Watts 2170 2090 2020 1950 Amps 10.2 9.95 9.75 9.56
Lb/h 216 196 176 156
Btu/h 19200 17300 15300 13300 11400 Watts 2320 2280 2230 2190 2150 Amps 10.8 10.7 10.6 10.5 10.4
Lb/h 252 230 207 185 162
Btu/h 22800 20500 18200 15900 13500 Watts 2450 2450 2440 2430 2420 Amps 11.4 11.4 11.4 11.4 11.4
Lb/h 294 269 245 220 196
Btu/h 26700 24100 21500 18800 16200 13500 10900 Watts 2570 2600 2630 2650 2670 2700 2720 Amps 11.9 12.1 12.2 12.4 12.5 12.6 12.7
Lb/h 340 314 288 262 235 208 181
Btu/h 31000 28100 25200 22200 19300 16300 13300 Watts 2670 2740 2800 2860 2910 2970 3020 Amps 12.4 12.7 13.0 13.3 13.5 13.7 14.0
Lb/h 392 364 337 308 280 251 221
Btu/h 35800 32600 29300 26100 22800 19500 16200 Watts 2750 2850 2950 3050 3140 3230 3320 Amps 12.8 13.3 13.7 14.1 14.5 14.9 15.2
Lb/h 448 419 390 360 330 299 268
Btu/h 40900 37400 33900 30300 26800 23200 19600
25
30
35
40
45
50
55
Watts 2810 2950 3080 3220 3350 3480 3600 Amps 13.2 13.8 14.4 15.0 15.5 16.0 16.5
Lb/h 509 479 448 417 385 353 320
Btu/h 46400 42700 38800 35000 31100 27200 23300 Watts 2840 3020 3200 3370 3540 3700 3860 Amps 13.4 14.2 14.9 15.7 16.4 17.1 17.7
Lb/h 573 542 510 478 445 412 377
Btu/h 52300 48200 44200 40000 35900 31700 27500 Watts 2850 3070 3280 3500 3700 3910 4110 Amps 13.4 14.4 15.4 16.3 17.2 18.0 18.8
Lb/h 640 609 576 543 509 475 439
Btu/h 58500 54200 49800 45400 41000 36600 32100 Watts 2820 3090 3340 3600 3850 4090 4330 Amps 13.4 14.6 15.7 16.8 17.9 18.9 19.9
Lb/h 711 679 646 612 578 542 506
Btu/h 65100 60500 55900 51200 46500 41800 37000 Watts 2770 3080 3380 3670 3960 4250 4530 Amps 13.1 14.6 15.9 17.2 18.5 19.7 20.9
Lb/h 785 753 719 685 650 613 576
Btu/h 71900 67100 62200 57300 52400 47400 42300 Watts 2680 3040 3380 3720 4060 4380 4700 Amps 12.7 14.4 15.9 17.5 18.9 20.3 21.7
Lb/h 861 829 795 760 725 688 650
Btu/h 79100 74000 68900 63800 58500 53300 48000 Watts 2570 2960 3350 3740 4120 4490 4850 Amps 12.1 14.0 15.8 17.5 19.2 20.8 22.4
Lb/h 940 907 874 839 803 766 728
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 3.511398E+04 2.669351E+03 1.167313E+01 4.334676E+02 C2 1.153265E+03 -2.911056E+01 -1.057178E-01 1.034165E+01 C3 -2.004034E+02 -4.658915E+00 -1.399424E-02 -2.316460E+00 C4 7.455840E+00 -4.867437E-01 -2.240618E-03 7.718393E-02 C5 -5.850715E+00 7.673005E-01 3.283134E-03 -2.386078E-02 C6 3.651690E-02 4.958913E-03 4.809938E-05 8.673915E-04 C7 -1.883373E-02 -2.557578E-03 -2.480743E-05 -4.473604E-04 C8 1.749664E-02 2.376004E-03 2.304625E-05 4.156003E-04 C9 -4.289976E-03 -5.825691E-04 -5.650677E-06 -1.019005E-04
C10 -1.339213E-04 -1.818621E-05 -1.763986E-07 -3.181053E-06
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature
Loading...