Performance Data Sheet
AVA5538WXN
General Information
Model AVA5538WXN Refrigerant R-407C/R-22
Test Condition ARI (R407C) Performance Test Voltage 230V ~ 60HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type PSC
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 12000 9940
Watts 1110 1180
Amps 5.05 5.39
Lb/h
Btu/h 12500 10600 8640
Watts 1260 1350 1370
Amps 5.87 6.18 6.53
Lb/h
Btu/h 13400 11700 9840 7960
Watts 1400 1520 1560 1550
Amps 6.66 6.96 7.29 7.60
Lb/h 27.8 35.1 44.1 52.8
Btu/h 14800 13200 11400 9600 7740
Watts 1540 1680 1750 1760 1730
Amps 7.40 7.72 8.06 8.36 8.59
Lb/h 100 99.2 100 102 101
Btu/h 16700 15100 13400 11600 9700
Watts 1670 1830 1930 1970 1960
Amps 8.09 8.45 8.82 9.14 9.38
Lb/h 166 158 153 148 140
Btu/h 19000 17400 15700 13900 11900 9980 7970
Watts 1790 1980 2100 2170 2190 2170 2120
Amps 8.70 9.13 9.55 9.92 10.2 10.3 10.3
Lb/h 227 214 202 192 180 164 142
Btu/h 21700 20100 18300 16500 14500 12400 10300
Watts 1890 2110 2260 2360 2410 2420 2400
Amps 9.22 9.75 10.3 10.7 11.0 11.2 11.2
Lb/h 284 265 250 235 219 199 174
Btu/h 24900 23200 21400 19400 17200 15000 12700
Watts 1980 2230 2410 2540 2620 2650 2660
Amps 9.64 10.3 10.9 11.4 11.8 12.1 12.1
Lb/h 337 315 296 278 259 237 209
Btu/h 28500 26700 24700 22600 20300 17800 15300
25
30
35
40
45
50
55
Watts 2050 2330 2540 2700 2810 2880 2920
Amps 9.94 10.7 11.5 12.1 12.6 13.0 13.1
Lb/h 387 363 342 322 301 277 248
Btu/h 32500 30500 28400 26000 23500 20900 18100
Watts 2090 2410 2660 2850 2990 3090 3170
Amps 10.1 11.1 12.0 12.8 13.4 13.9 14.1
Lb/h 436 411 388 367 346 322 293
Btu/h 36900 34800 32400 29800 27000 24100 21000
Watts 2110 2470 2750 2980 3150 3290 3400
Amps 10.1 11.3 12.4 13.4 14.2 14.8 15.1
Lb/h 484 458 436 415 394 371 343
Btu/h 41700 39300 36700 33800 30700 27500 24100
Watts 2110 2500 2820 3080 3300 3470 3610
Amps 10.0 11.4 12.7 13.9 14.9 15.6 16.1
Lb/h 532 507 486 467 448 426 400
Btu/h 46900 44200 41200 38100 34700 31100 27300
Watts 2070 2500 2860 3160 3410 3630 3810
Amps 9.71 11.4 12.9 14.3 15.5 16.4 17.1
Lb/h 581 558 539 523 506 487 465
Btu/h 52400 49400 46100 42600 38800 34800 30600
Watts 2010 2470 2880 3220 3510 3760 3980
Amps 9.22 11.1 12.9 14.6 16.0 17.2 18.1
Lb/h 632 612 597 584 571 556 538
Btu/h 58300 54900 51300 47300 43100 38700 34000
Watts 1910 2420 2860 3240 3570 3870 4130
Amps 8.53 10.7 12.8 14.7 16.4 17.9 19.0
Lb/h 686 670 659 651 643 633 620
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 2.176587E+04 -3.039180E+03 1.044707E+01 4.256391E+02
C2 7.156474E+01 -1.513600E+01 -1.572642E-03 2.749298E+01
C3 1.129451E+01 1.072127E+02 -1.517345E-01 -1.007415E+01
C4 1.587589E+01 -4.392883E-01 -5.285512E-03 -3.008894E-01
C5 4.704575E+00 5.437880E-01 2.860122E-03 -1.899464E-01
C6 -1.547328E+00 -7.486317E-01 1.991497E-03 1.024099E-01
C7 -1.301428E-02 -3.374795E-03 -1.886498E-05 1.174246E-03
C8 -8.403812E-02 3.212512E-03 5.113773E-05 2.235872E-03
C9 -1.888984E-02 -2.388629E-04 -1.312235E-05 2.359192E-04
C10 3.991555E-03 1.553651E-03 -7.131310E-06 -3.418920E-04
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature