Performance Data Sheet
AVA5538WXG
General Information
Model AVA5538WXG Refrigerant R-407C/R-22
Test Condition ARI (R407C) Performance Test Voltage 460V 3~ 60HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type 3PH
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 12200 10100
Watts 1090 1160
Amps 1.56 1.65
Lb/h
Btu/h 12600 10700 8750
Watts 1240 1320 1350
Amps 1.80 1.88 1.98
Lb/h
Btu/h 13600 11800 9960 8060
Watts 1380 1490 1530 1520
Amps 2.02 2.11 2.20 2.29
Lb/h 27.6 34.6 43.6 52.6
Btu/h 15000 13300 11600 9720 7830
Watts 1510 1650 1720 1730 1700
Amps 2.24 2.33 2.43 2.52 2.58
Lb/h 101 100 101 102 102
Btu/h 16900 15300 13500 11700 9820
Watts 1640 1800 1890 1930 1920
Amps 2.44 2.55 2.65 2.75 2.81
Lb/h 168 160 155 149 142
Btu/h 19200 17600 15900 14000 12100 10100 8070
Watts 1750 1940 2060 2130 2140 2130 2080
Amps 2.61 2.75 2.87 2.98 3.06 3.09 3.07
Lb/h 230 216 205 194 182 166 144
Btu/h 22000 20400 18600 16700 14600 12500 10400
Watts 1850 2070 2220 2310 2360 2370 2350
Amps 2.77 2.93 3.08 3.21 3.30 3.35 3.34
Lb/h 288 269 253 238 222 202 176
Btu/h 25200 23500 21600 19600 17400 15200 12900
Watts 1940 2180 2360 2490 2560 2600 2610
Amps 2.89 3.09 3.27 3.43 3.55 3.62 3.63
Lb/h 342 319 300 282 262 240 212
Btu/h 28900 27000 25000 22800 20500 18100 15500
25
30
35
40
45
50
55
Watts 2010 2280 2490 2650 2760 2820 2860
Amps 2.97 3.22 3.44 3.64 3.79 3.89 3.92
Lb/h 393 368 346 326 305 281 251
Btu/h 32900 30900 28700 26400 23800 21100 18300
Watts 2050 2360 2600 2790 2930 3030 3110
Amps 3.02 3.32 3.59 3.83 4.03 4.16 4.23
Lb/h 442 416 393 372 350 326 296
Btu/h 37400 35200 32800 30200 27400 24400 21300
Watts 2070 2420 2690 2920 3090 3230 3330
Amps 3.03 3.39 3.72 4.01 4.25 4.43 4.53
Lb/h 491 464 442 421 399 376 347
Btu/h 42200 39800 37100 34200 31100 27800 24400
Watts 2070 2450 2760 3020 3230 3400 3540
Amps 2.99 3.42 3.81 4.16 4.46 4.69 4.84
Lb/h 539 514 492 473 453 431 405
Btu/h 47500 44700 41800 38500 35100 31500 27700
Watts 2030 2450 2800 3100 3350 3550 3730
Amps 2.90 3.40 3.86 4.28 4.64 4.93 5.14
Lb/h 589 565 546 529 512 493 470
Btu/h 53100 50000 46700 43100 39300 35200 31000
Watts 1970 2430 2820 3150 3440 3680 3900
Amps 2.76 3.34 3.88 4.37 4.80 5.15 5.42
Lb/h 640 620 604 591 578 563 544
Btu/h 59000 55600 51900 47900 43700 39200 34500
Watts 1870 2370 2800 3180 3500 3790 4050
Amps 2.55 3.22 3.85 4.42 4.93 5.36 5.70
Lb/h 694 678 667 659 651 641 628
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 2.198378E+04 -2.958285E+03 2.967369E+00 4.515298E+02
C2 7.241699E+01 -1.517875E+01 -5.448261E-03 2.785484E+01
C3 1.283024E+01 1.046307E+02 -3.989027E-02 -1.074787E+01
C4 1.607608E+01 -4.230805E-01 -1.538005E-03 -3.088406E-01
C5 4.763482E+00 5.347835E-01 9.093753E-04 -1.904438E-01
C6 -1.578495E+00 -7.301936E-01 5.432569E-04 1.082809E-01
C7 -1.319783E-02 -3.313255E-03 -5.664283E-06 1.208844E-03
C8 -8.508679E-02 3.089133E-03 1.498044E-05 2.283136E-03
C9 -1.912777E-02 -2.257504E-04 -4.035187E-06 2.252775E-04
C10 4.074805E-03 1.512380E-03 -1.981165E-06 -3.584238E-04
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature