Tecumseh AVA5538EXT Performance Data Sheet

Performance Data Sheet
AVA5538EXT
General Information
Model AVA5538EXT Refrigerant R-22 Test Condition ASHRAE Performance Test Voltage 230V 3~ 60HZ Return Gas -6.7°C (20°F) SUPERHEAT Motor Type 3PH
Performance Information
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 10800 10000 Watts 1420 1460 Amps 5.35 5.43
Lb/h 140 135
Btu/h 12300 11300 10200 Watts 1500 1550 1590 Amps 5.47 5.59 5.63
Lb/h 158 151 143
Btu/h 14300 13000 11800 10500 Watts 1590 1650 1700 1730 Amps 5.61 5.77 5.85 5.86
Lb/h 181 173 163 152
Btu/h 16700 15300 13800 12400 10900 Watts 1680 1760 1820 1870 1880 Amps 5.76 5.96 6.09 6.15 6.14
Lb/h 211 201 190 177 163
Btu/h 19600 17900 16300 14600 12900 Watts 1770 1870 1950 2010 2040 Amps 5.91 6.16 6.34 6.45 6.49
Lb/h 246 234 222 207 192
Btu/h 22900 21000 19100 17200 15300 13400 11500 Watts 1860 1980 2080 2150 2210 2230 2220 Amps 6.06 6.36 6.59 6.75 6.85 6.89 6.86
Lb/h 286 273 259 243 226 207 187
Btu/h 26600 24500 22400 20300 18100 15900 13800 Watts 1950 2080 2200 2300 2370 2420 2430 Amps 6.20 6.55 6.83 7.05 7.21 7.31 7.35
Lb/h 330 316 301 284 265 245 223
Btu/h 30700 28400 26000 23700 21200 18800 16400 Watts 2020 2170 2310 2440 2530 2600 2640 Amps 6.33 6.73 7.07 7.35 7.57 7.74 7.84
Lb/h 379 364 347 329 309 287 264
Btu/h 35200 32600 30000 27400 24700 22100 19400
25
30
35
40
45
50
55
Watts 2090 2260 2420 2570 2690 2780 2850 Amps 6.45 6.90 7.29 7.63 7.91 8.15 8.33
Lb/h 432 415 397 378 357 334 309
Btu/h 40000 37200 34300 31400 28500 25600 22600 Watts 2140 2330 2510 2680 2830 2950 3050 Amps 6.54 7.04 7.49 7.89 8.24 8.55 8.80
Lb/h 488 470 451 431 408 384 358
Btu/h 45100 42000 38900 35800 32600 29400 26200 Watts 2170 2380 2590 2790 2960 3110 3230 Amps 6.60 7.16 7.67 8.13 8.55 8.92 9.25
Lb/h 547 529 508 487 463 438 410
Btu/h 50500 47200 43800 40400 36900 33400 29900 Watts 2180 2420 2650 2870 3080 3260 3410 Amps 6.63 7.25 7.82 8.35 8.83 9.28 9.68
Lb/h 610 590 569 546 521 494 466
Btu/h 56200 52600 48900 45200 41500 37700 33900 Watts 2160 2430 2690 2940 3170 3380 3560 Amps 6.63 7.30 7.93 8.53 9.08 9.60 10.1
Lb/h 674 654 631 608 582 554 524
Btu/h 62200 58200 54300 50300 46200 42200 38100 Watts 2120 2410 2700 2980 3240 3480 3700 Amps 6.58 7.31 8.01 8.67 9.29 9.89 10.4
Lb/h 741 720 696 671 645 616 585
Btu/h 68300 64100 59800 55500 51200 46900 42500 Watts 2050 2370 2680 2990 3290 3560 3810 Amps 6.47 7.27 8.03 8.76 9.46 10.1 10.8
Lb/h 809 787 763 737 710 680 648
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 2.635708E+04 1.015914E+03 1.351728E+00 2.630817E+02 C2 8.565630E+02 2.923185E+00 -1.357634E-02 8.422588E+00 C3 -9.201979E+01 2.195577E+00 8.652784E-02 -4.965194E-01 C4 1.030241E+01 -1.710330E-01 -1.790671E-04 9.870710E-02 C5 -3.888606E+00 9.630292E-02 2.382259E-04 -2.133620E-02 C6 -4.603641E-01 1.452880E-01 -4.025994E-04 -2.132951E-04 C7 -3.099491E-02 -4.286506E-03 -7.120642E-06 -4.935003E-04 C8 -1.538581E-02 2.402820E-03 3.277509E-06 1.157785E-04 C9 -1.949807E-03 1.223892E-03 3.835747E-06 -4.331459E-05
C10 1.267111E-03 -8.638976E-04 1.148846E-07 -2.170632E-05
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature
Loading...