Tecumseh AVA5535EXT Performance Data Sheet

Performance Data Sheet
AVA5535EXT
General Information
Model AVA5535EXT Refrigerant R-22 Test Condition ASHRAE Performance Test Voltage 230V 3~ 60HZ Return Gas -6.7°C (20°F) SUPERHEAT Motor Type 3PH
Performance Information
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 12800 9600 Watts 1320 1350 Amps 4.45 4.21
Lb/h 170 129
Btu/h 14300 11000 8870 Watts 1460 1510 1520 Amps 4.71 4.59 4.41
Lb/h 188 147 123
Btu/h 16100 12700 10500 8950 Watts 1580 1660 1690 1680 Amps 4.94 4.93 4.87 4.75
Lb/h 210 169 144 128
Btu/h 18300 14700 12400 10700 9350 Watts 1690 1790 1850 1870 1840 Amps 5.14 5.25 5.29 5.27 5.18
Lb/h 237 194 169 153 140
Btu/h 20800 17100 14600 12800 11300 Watts 1790 1910 2000 2040 2050 Amps 5.31 5.54 5.68 5.75 5.75
Lb/h 267 224 198 182 168
Btu/h 23700 19800 17100 15200 13600 11700 9070 Watts 1870 2020 2130 2200 2230 2230 2180 Amps 5.44 5.79 6.04 6.21 6.29 6.30 6.23
Lb/h 301 257 231 214 200 180 148
Btu/h 26900 22800 20000 17900 16100 14100 11400 Watts 1940 2110 2250 2350 2410 2430 2420 Amps 5.54 6.01 6.37 6.64 6.80 6.88 6.87
Lb/h 340 295 268 250 236 216 184
Btu/h 30500 26200 23200 20900 19000 16800 13900 Watts 1990 2190 2350 2480 2570 2630 2650 Amps 5.60 6.19 6.67 7.03 7.28 7.43 7.49
Lb/h 382 336 308 291 275 255 223
Btu/h 34500 30000 26700 24300 22100 19700 16700
25
30
35
40
45
50
55
Watts 2030 2260 2450 2600 2720 2810 2860 Amps 5.62 6.34 6.93 7.39 7.73 7.96 8.07
Lb/h 429 382 353 335 319 298 266
Btu/h 38900 34100 30600 27900 25600 23000 19800 Watts 2060 2310 2530 2710 2860 2980 3070 Amps 5.61 6.45 7.15 7.71 8.14 8.44 8.62
Lb/h 479 432 402 382 366 345 312
Btu/h 43600 38600 34800 31900 29300 26600 23100 Watts 2070 2350 2590 2800 2990 3140 3260 Amps 5.55 6.52 7.34 8.00 8.52 8.90 9.14
Lb/h 534 485 454 434 417 396 362
Btu/h 48800 43400 39400 36200 33400 30400 26800 Watts 2070 2370 2640 2890 3100 3280 3440 Amps 5.46 6.56 7.48 8.25 8.86 9.32 9.63
Lb/h 594 543 511 490 472 450 416
Btu/h 54300 48700 44400 40900 37800 34600 30700 Watts 2060 2380 2680 2950 3200 3410 3600 Amps 5.33 6.55 7.59 8.46 9.16 9.70 10.1
Lb/h 657 605 572 550 531 508 474
Btu/h 60300 54300 49700 46000 42600 39100 35000 Watts 2030 2380 2710 3010 3280 3530 3760 Amps 5.15 6.50 7.66 8.64 9.43 10.0 10.5
Lb/h 725 671 637 614 594 570 536
Btu/h 66600 60300 55400 51400 47700 43900 39500 Watts 1980 2360 2720 3050 3360 3640 3900 Amps 4.93 6.41 7.69 8.77 9.66 10.4 10.9
Lb/h 796 742 706 681 661 636 601
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 1.497182E+05 -6.092260E+02 1.240413E+00 2.088040E+03 C2 8.075403E+02 -4.121311E+00 -2.422159E-01 7.943371E+00 C3 -3.380190E+03 4.474182E+01 8.806568E-02 -4.896768E+01 C4 9.893996E+00 -3.164213E-01 -8.162832E-04 9.318654E-02 C5 -5.336921E+00 1.680352E-01 4.458732E-03 -4.184538E-02 C6 2.829331E+01 -1.955998E-01 -5.534470E-04 4.228916E-01 C7 8.011510E-03 -1.115325E-04 -1.388781E-06 3.321045E-05 C8 -3.581815E-02 5.649835E-04 2.028494E-06 -1.583271E-04 C9 1.374183E-02 1.766729E-03 -1.220548E-05 1.648757E-04
C10 -8.227391E-02 -5.713898E-05 7.775288E-07 -1.251190E-03
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature
Loading...