Tecumseh Compressor Company
October 4, 2012
Indoor Condensing Units
Model: AKA9473ZXAXC BoM: 2B1177-1 R-404A 0.92 HP AIRCOOLED
AKA9473ZXAXC
Model
35.0 18.0 12.0 10.15 1/2” S 3/8” S 7.30 lbs 800 38.5 ---
* F = Flare, S = Solder, RF or RS = Rotolock with Flare or Solder Connections, C = Compression Fitting
Evaporator T
°F PSIG BTUH Watts Cond T BTUH Watts Cond T BTUH Watts Cond T BTUH Watts Cond T
-10 23.2 4323 993 89 3532 1008 100 3027 987 109 1633 949 116
-5 28.1 4814 1040 91 4025 1059 101 3476 1049 110 2190 1021 118
0 32.8 5370 1090 92 4574 1113 102 3977 1113 112 2780 1095 119
5 37.9 5989 1142 93 5181 1169 104 4529 1179 113 3404 1170 121
10 43.3 6673 1197 95 5845 1228 105 5132 1248 114 4060 1248 123
15 49.1 7421 1254 97 6566 1290 106 5786 1319 116 4750 1328 124
20 55.5 8234 1313 99 7344 1354 108 6492 1392 117 5473 1409 126
25 62.2 9110 1376 100 8179 1421 110 7249 1468 119 6228 1492 128
30 69.5 10052 1440 102 9071 1491 111 8056 1546 120 7017 1577 130
35 77.2 11057 1507 104 10021 1563 113 8916 1626 122 7839 1665 131
40 85.5 12127 1576 107 11027 1638 115 9826 1708 124 8693 1754 133
45 94.3 13261 1648 109 12090 1715 117 10787 1793 126 9581 1844 135
Dimensions, inches Line Connection* Pumpdown Air Oil Ch Gr. Wt.
L W H CH Suction Liquid
Ambient Temperatures
80F 90F 100F 110F
60 Hz Performance
Return gas temp. 40F Evaporator Temp. 20F or less, 5F sub-cooling
Return gas temp. 65F for Evaporator Temp. > 20F, 5F sub-cooling
90 F 90%
SCFM Oz. Lbs.
October 4, 2012
Specifications/ Parts:
Model AKA9473ZXAXC
Unit Bill of Material 2B1177-1 Fan Motor RLA 0.4 Each
Nominal Volts-Hz-Ph 115-60-1 Fan Blade 515-10004 (2)
Refrigeration Range -10° to 45°F Fan Guard 570-10000 (2)
Design Pressure Low 181 Fan Shroud 707-10000
Design Pressure High 450 Dual Pressure Control 14955206
Voltage Range 103 to 127 Condenser 506-10005
Min. Circuit Ampacity 15.9 Receiver Tank with Valve 510-10003
Max. Fuse Size (amps) 25 Liquid Filter 70081
Compressor Model AKA9462ZXA Sight Glass 70084
Comp. Bill of Material AK172AT-038-P2 Suction Valve 31582-1
Compressor RLA/LRA 12.1 / 68
Overload 8300CRTK51 Discharge Valve 56630-A
Relay 820ARR3D10 Suction Filter * N/A
Run Capacitor 85PR370F20 Accumulator * N/A
Run Capacitor Rating 25MFD 370V(M) VDE Crankcase Heater N/A
Start Capacitor 85PS250C30 Defrost Timer * N/A
Start Capacitor Rating 72-88 MFD 250V VDE * = Equipped Units Only
Contactor N/A
Unit Drawing DGU1909-121
Wiring Diagram 91267-01
Fan Motor 810-10007 (2)
Rotolock Valve Gasket 30233
Electrical Diagram