Tecumseh AKA9464ZXDLS User Manual

AKA9464XDLS_Rel
AKA9464ZXDLS
Overall Dimensions, inch (mm)
Line connections
Pump down
Air flow
Oil Ch.
Gross weight
L W H
Suction
Liquid
90% @ 90oF
SCFM
Oz.
Lbs. (kg)
26.55 (674)
28.94 (735)
26.08 (662)
1/2"
3/8"
15.70 lbs
750
17.3
190 (91)
Factory charge 20 psig dry air, MUST BE EVACUATED
Evaporator
Ambient Temperatures
80°F
90°F
95°F
100°F
110°F
T, °F
PSIG
BTUH
Watts
Cond T
BTUH
Watts
Cond T
BTUH
Watts
Cond T
BTUH
Watts
Cond T
BTUH
Watts
Cond T
-10
23.2
3100
980
96
3100
970
98
2800
980
101
2500
980
106
2000
970
118
-5
27.5
3600
1040
97
3500
1030
99
3300
1040
103
3000
1040
108
2400
1040
119 0 32.1
4100
1090
98
4100
1090
100
3800
1100
104
3500
1110
109
2900
1120
120 5 37.0
4700
1150
100
4700
1150
101
4400
1160
105
4100
1170
110
3400
1190
121
10
42.4
5300
1210
101
5300
1210
102
5000
1220
106
4700
1240
111
3900
1260
123
15
48.2
6000
1270
102
6000
1270
104
5700
1280
108
5300
1300
113
4500
1330
124
20
54.5
6800
1320
104
6700
1330
105
6400
1350
109
6000
1370
114
5100
1410
125
25
61.2
7700
1380
105
7500
1390
107
7200
1410
110
6800
1430
115
5700
1480
127
30
68.4
8600
1440
107
8400
1450
108
8000
1470
112
7500
1490
117
6400
1550
128
35
76.1
9500
1500
108
9300
1510
110
8900
1530
113
8400
1560
119
7100
1620
130
40
84.4
10600
1550
110
10300
1570
111
9800
1590
115
9200
1620
120
7900
1690
132
Performance @ 60 Hz, Return gas 40oF below 20oF Evaporator and 65oF above 20oF evaporator, Sub Cooling 5oF
TPC January 26, 2016
TECUMSEH OUTDOOR
CONDENSING UNIT
Model AKA9464ZXDLS BOM 32L751-6U
Air Cooled 3/4 HP Application Commercial Temp Refrigerant R404A Volts-Hz-Ph. 208-230/60/1
AKA9464ZXDLS_Rel
Parts/Specifications
Unit BOM
32L751-6U
Fan Motor
810F050C20
Adjustable Fan Control
----
Unit MODEL
AKA9464ZXDLS
Replacement Fan Motor
50W230
Fixed Fan Control
----
Fan Motor Qty
1
Refrigeration Range
-10°F to 45°F
Fan Motor RLA
0.7
Defrost Timer
LTCG-T1
Design Pressure Low / High
181 / 450
Fan Blade
51568-1
Electric Defrost Timer
----
Volts - HZ - Ph
208-230V ~ 60HZ
Fan Guard
70831
Voltage Range
187 - 253
Receiver Heater
-----
Min. Circuit Ampacity
8.16
Shroud
70727-2
Receiver Heater Thermostat
-----
Max. Fuse Size
15
Condenser
50857-1
C/Case Heater
92123-2
Compressor MODEL
AKA9455ZXD
Receiver
51082-1K
Unit Drawing
DGU1909-L421
Compressor BOM
AK171ET-037-P2
Accumulator
----
Wiring Diagram
WD21-105
Compressor LRA
31
Liquid Filter
70139
Compressor RLA
5.83
Sight Glass
70084-S
Suction Filter
----
OverLoad
8300MRAG29
Replacement Kit - O/L
K90-20
High Pressure Switch
84095-2L
Relay
8200RVAM01
Low Pressure Control
84026-2
Replacement Kit - Relay
K71-17
Low Pressure Switch
----
Run Capacitor
85PR370E36
Head Master Valve
70083
Replacement Kit Run Cap.
K150-03
Check Valve
----
Loose Optional Items
Start Capacitor
85685
Liquid Valve
31590
Disconnect Switch
LDSG-311
Replacement Kit Start Cap
K146-02
Suction Valve (Base)
56500-K08
Liquid Solenoid
KSVC-285
Contactor
91014H
Hail Louver
----
TPC January 26, 2016
Loading...