Tecumseh AJC5519EXD User Manual

Performance Data Sheet
AJC5519EXD
General Information
Model AJC5519EXD Refrigerant R22 Test Condition ASHRAE Test Voltage 230V ~ 60HZ Return Gas 35°C (95°F) RETURN GAS Motor Type PSC
Performance Information
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140 150
Btu/h Watts 131 317 Amps 5.50 4.78
Lb/h
Btu/h 1890 220 Watts 328 519 632 Amps 5.99 5.43 4.83
Lb/h 21.0 1.31
Btu/h 4190 2530 1050 Watts 516 709 831 884 Amps 6.45 6.02 5.58 5.12
Lb/h 46.7 28.1 11.0
Btu/h 6490 4850 3360 2040 895 Watts 694 887 1020 1080 1090 Amps 6.87 6.57 6.27 5.94 5.61
Lb/h 72.4 54.9 38.7 23.8 10.2
Btu/h 8810 7160 5670 4330 3140 Watts 862 1050 1190 1270 1300 Amps 7.25 7.08 6.90 6.71 6.51
Lb/h 98.1 81.7 66.4 52.2 39.1
Btu/h 11100 9490 7980 6610 5370 4270 3310 Watts 1020 1210 1350 1440 1490 1480 1430 Amps 7.60 7.55 7.48 7.41 7.33 7.25 7.17
Lb/h 124 108 94.0 80.5 68.0 56.4 45.7
Btu/h 13500 11800 10300 8890 7610 6440 5400 Watts 1170 1350 1490 1590 1660 1680 1660 Amps 7.92 7.97 8.01 8.04 8.07 8.11 8.15
Lb/h 150 135 122 109 96.8 85.5 75.0
Btu/h 15800 14100 12600 11200 9830 8600 7480 6450 Watts 1310 1480 1620 1730 1810 1860 1870 1850 Amps 8.21 8.35 8.48 8.61 8.75 8.89 9.04 9.21
Lb/h 176 162 150 137 126 115 104 94.4
Btu/h 18100 16500 14900 13400 12100 10800 9540 8420
25
30
35
40
45
50
55
Watts 1440 1600 1740 1860 1950 2010 2050 2070 Amps 8.48 8.69 8.91 9.13 9.35 9.59 9.84 10.1
Lb/h 202 190 178 166 155 144 134 124
Btu/h 20500 18800 17200 15700 14300 12900 11600 10400 Watts 1560 1710 1850 1970 2070 2150 2220 2270 Amps 8.71 9.00 9.29 9.58 9.89 10.2 10.5 10.9
Lb/h 229 217 206 195 184 173 163 153
Btu/h 22800 21200 19600 18000 16500 15000 13600 12300 Watts 1670 1810 1940 2060 2170 2270 2360 2440 Amps 8.92 9.26 9.62 9.98 10.4 10.7 11.2 11.6
Lb/h 255 245 234 224 213 203 193 182
Btu/h 25200 23500 21900 20300 18700 17200 15700 14200 Watts 1770 1900 2020 2140 2250 2370 2480 2590 Amps 9.10 9.50 9.90 10.3 10.8 11.2 11.7 12.2
Lb/h 283 273 263 253 243 233 222 212
Btu/h 27600 25900 24200 22500 20900 19300 17700 16200 Watts 1860 1970 2080 2200 2320 2450 2580 2720 Amps 9.26 9.69 10.1 10.6 11.1 11.6 12.1 12.7
Lb/h 310 301 292 282 273 263 252 242
Btu/h 29900 28200 26500 24800 23100 21400 19700 18100 Watts 1940 2030 2140 2250 2370 2510 2660 2830 Amps 9.40 9.86 10.3 10.8 11.4 11.9 12.5 13.1
Lb/h 338 330 321 312 303 293 282 272
Btu/h 32300 30600 28800 27100 25300 23500 21700 19900 Watts 2020 2090 2170 2280 2410 2560 2720 2910 Amps 9.51 9.99 10.5 11.0 11.6 12.1 12.8 13.4
Lb/h 366 359 351 342 333 323 313 302
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 2.557054E+04 -3.155151E+03 8.166264E+00 2.623709E+02 C2 3.336114E+02 8.934358E+01 -9.965755E-02 2.177772E+00 C3 -3.030097E+02 7.411084E+01 -8.207257E-04 -2.946394E+00 C4 6.073636E-01 1.146245E-01 1.008912E-03 4.922225E-03 C5 2.886703E+00 -1.281236E+00 1.975079E-03 5.084036E-02 C6 7.980859E-01 -3.294316E-01 -2.373447E-04 7.365602E-03 C7 -1.855283E-05 9.257302E-05 1.666764E-06 6.066512E-05 C8 -5.821414E-03 -3.878564E-03 -2.107140E-05 -5.581246E-05 C9 -1.605713E-02 7.457142E-03 3.428529E-06 -1.729943E-04
C10 1.115792E-04 5.556387E-05 5.554640E-07 -2.685455E-06
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature