Performance Data Sheet
AGC5568EXG
General Information
Model AGC5568EXG Refrigerant R-22
Test Condition ASHRAE Performance Test Voltage 460V 3~ 60HZ
Return Gas -6.7°C (20°F) SUPERHEAT Motor Type 3PH
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 27000 23200
Watts 3710 3530
Amps 5.52 5.32
Lb/h 352 312
Btu/h 28100 24400 21000
Watts 3780 3650 3520
Amps 5.81 5.66 5.51
Lb/h 364 326 291
Btu/h 30100 26300 22900 19800
Watts 3860 3790 3710 3620
Amps 6.08 5.98 5.88 5.78
Lb/h 386 350 316 285
Btu/h 32800 29100 25600 22400 19500
Watts 3960 3940 3910 3870 3820
Amps 6.34 6.30 6.25 6.20 6.14
Lb/h 418 383 351 320 291
Btu/h 36400 32600 29000 25700 22600
Watts 4070 4100 4120 4130 4120
Amps 6.58 6.61 6.62 6.61 6.60
Lb/h 460 427 395 365 336
Btu/h 40800 36900 33200 29700 26400 23400 20600
Watts 4200 4280 4340 4390 4440 4470 4500
Amps 6.82 6.91 6.97 7.02 7.06 7.09 7.13
Lb/h 511 480 449 419 390 362 334
Btu/h 46000 42000 38200 34500 31000 27600 24500
Watts 4340 4460 4570 4670 4760 4830 4900
Amps 7.04 7.20 7.32 7.42 7.51 7.59 7.67
Lb/h 572 542 512 483 453 424 395
Btu/h 52000 47900 43900 40000 36200 32500 29000
Watts 4490 4660 4810 4950 5080 5200 5310
Amps 7.25 7.48 7.67 7.83 7.96 8.09 8.21
Lb/h 642 614 585 555 525 495 465
Btu/h 58800 54600 50300 46200 42100 38100 34200
25
30
35
40
45
50
55
Watts 4650 4870 5060 5250 5420 5570 5720
Amps 7.45 7.74 8.00 8.22 8.42 8.59 8.75
Lb/h 722 694 666 637 607 576 544
Btu/h 66500 62000 57500 53100 48700 44300 40000
Watts 4820 5080 5320 5550 5750 5950 6130
Amps 7.63 8.00 8.33 8.61 8.86 9.09 9.30
Lb/h 810 784 756 727 696 664 631
Btu/h 74900 70200 65500 60700 55900 51200 46400
Watts 5010 5310 5590 5850 6100 6330 6540
Amps 7.79 8.25 8.65 9.00 9.31 9.59 9.85
Lb/h 907 882 855 826 795 762 726
Btu/h 84200 79200 74200 69100 63900 58700 53400
Watts 5210 5550 5870 6170 6450 6710 6960
Amps 7.94 8.48 8.95 9.38 9.75 10.1 10.4
Lb/h 1010 990 963 934 902 867 830
Btu/h 94200 89000 83600 78100 72500 66800 61100
Watts 5420 5800 6160 6490 6800 7100 7380
Amps 8.08 8.70 9.25 9.75 10.2 10.6 11.0
Lb/h 1130 1110 1080 1050 1020 981 942
Btu/h 99500 93800 87900 81800 75700 69300
Watts 5650 6060 6450 6820 7160 7490 7800
Amps 8.20 8.91 9.54 10.1 10.6 11.1 11.5
Lb/h 1250 1230 1200 1170 1140 1100 1060
Btu/h 98400 91800 85100 78200
Watts 5880 6330 6750 7150 7530 7880 8220
Amps 8.30 9.10 9.82 10.5 11.1 11.6 12.1
Lb/h 1380 1360 1340 1310 1270 1230 1190
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 6.970257E+04 3.428934E+03 5.143732E+00 7.597886E+02
C2 3.429751E+02 -7.126461E+01 -8.549490E-02 5.643222E-01
C3 -5.144058E+02 1.712443E+01 4.078025E-02 -4.962248E+00
C4 2.141445E+01 5.265637E-01 -7.186346E-04 2.070175E-01
C5 7.213508E+00 1.260404E+00 2.162684E-03 1.322635E-01
C6 4.036093E-01 -1.609568E-01 -4.290640E-04 8.117213E-03
C7 -2.557603E-03 -3.147477E-04 -5.659395E-07 -2.185138E-04
C8 -6.257831E-02 -3.192580E-03 5.950741E-06 -1.333385E-04
C9 -4.512808E-02 -1.351227E-03 -5.740515E-06 -5.878276E-04
C10 3.286428E-03 3.769354E-04 1.321643E-06 5.863681E-06
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature