Performance Data Sheet
AGA5573EXG
General Information
Model AGA5573EXG Refrigerant R-22
Test Condition ASHRAE Performance Test Voltage 460V 3~ 60HZ
Return Gas -6.7°C (20°F) SUPERHEAT Motor Type 3PH
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 16300 13300
Watts 2640 2600
Amps 4.71 4.63
Lb/h 211 178
Btu/h 20500 17300 14500
Watts 2970 2980 2930
Amps 5.19 5.18 5.10
Lb/h 264 231 201
Btu/h 25200 21900 18800 16000
Watts 3300 3360 3360 3300
Amps 5.65 5.71 5.71 5.65
Lb/h 322 290 260 231
Btu/h 30400 26900 23600 20600 17800
Watts 3620 3720 3770 3770 3700
Amps 6.09 6.22 6.29 6.30 6.25
Lb/h 386 354 324 295 267
Btu/h 36100 32400 28900 25700 22600
Watts 3930 4080 4170 4220 4210
Amps 6.52 6.72 6.85 6.93 6.95
Lb/h 455 424 394 365 336
Btu/h 42300 38400 34700 31200 27900 24700 21700
Watts 4240 4420 4560 4650 4700 4690 4640
Amps 6.94 7.19 7.39 7.53 7.62 7.66 7.65
Lb/h 530 499 469 440 411 382 353
Btu/h 49000 44900 41000 37200 33500 30000 26700
Watts 4530 4760 4940 5070 5160 5210 5220
Amps 7.34 7.64 7.90 8.10 8.26 8.37 8.43
Lb/h 610 580 550 520 491 461 431
Btu/h 56300 51900 47700 43600 39700 35800 32100
Watts 4820 5080 5300 5470 5610 5710 5760
Amps 7.72 8.07 8.38 8.64 8.86 9.03 9.16
Lb/h 695 665 636 606 576 545 514
Btu/h 64000 59400 55000 50600 46300 42000 37900
25
30
35
40
45
50
55
Watts 5110 5390 5640 5860 6040 6180 6290
Amps 8.09 8.48 8.84 9.16 9.43 9.66 9.85
Lb/h 786 757 727 697 667 635 603
Btu/h 72300 67400 62700 58000 53300 48700 44200
Watts 5380 5700 5980 6230 6450 6630 6780
Amps 8.44 8.88 9.28 9.64 9.97 10.3 10.5
Lb/h 881 853 824 794 763 730 697
Btu/h 81000 75900 70900 65800 60800 55800 50800
Watts 5650 5990 6300 6580 6840 7060 7260
Amps 8.77 9.25 9.69 10.1 10.5 10.8 11.1
Lb/h 982 954 925 895 864 831 796
Btu/h 90300 84900 79500 74100 68700 63300 57900
Watts 5910 6270 6610 6920 7210 7470 7700
Amps 9.09 9.59 10.1 10.5 10.9 11.3 11.7
Lb/h 1090 1060 1030 1000 970 936 900
Btu/h 94400 88700 82900 77100 71300 65500
Watts 6170 6550 6900 7240 7560 7850 8120
Amps 9.39 9.92 10.4 10.9 11.4 11.8 12.2
Lb/h 1200 1170 1140 1110 1080 1050 1010
Btu/h 98300 92200 86000 79700 73400
Watts 6410 6810 7180 7540 7890 8210 8520
Amps 9.67 10.2 10.8 11.3 11.8 12.2 12.7
Lb/h 1310 1290 1260 1230 1200 1160 1120
Btu/h 95300 88500 81800
Watts 6650 7060 7450 7830 8200 8550 8890
Amps 9.94 10.5 11.1 11.6 12.1 12.6 13.1
Lb/h 1430 1410 1380 1350 1320 1280 1240
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 6.675723E+04 8.293566E+02 2.819887E+00 7.092726E+02
C2 1.167654E+03 1.897525E+01 1.161855E-02 9.941151E+00
C3 -5.484461E+02 5.667043E+01 6.603576E-02 -5.009688E+00
C4 1.258969E+01 3.438810E-01 3.705078E-04 1.061574E-01
C5 1.357120E+00 2.534018E-01 6.518455E-04 7.093764E-02
C6 1.172062E+00 -2.721109E-01 -3.181958E-04 1.414367E-02
C7 4.279784E-06 -1.330714E-05 -1.709391E-07 -8.779739E-05
C8 -2.976015E-02 -6.094304E-03 -8.558928E-06 4.562878E-05
C9 -2.909314E-02 3.725169E-03 3.734857E-06 -3.618235E-04
C10 6.908641E-06 -3.865981E-06 5.226838E-08 -2.579766E-05
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature