Performance Data Sheet
AGA5561WXN
General Information
Model AGA5561WXN Refrigerant R407C/R22
Test Condition ARI (R407C) Test Voltage 230V ~ 60HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type PSC
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140 150
Btu/h 21000 17000
Watts 1420 1180
Amps
Lb/h 256 215
Btu/h 21700 18100 14100
Watts 1960 1770 1580
Amps 3.66 4.19 4.88
Lb/h 264 231 185
Btu/h 23200 19900 16100 12100
Watts 2410 2270 2140 1990
Amps 7.99 8.40 8.98 9.58
Lb/h 280 253 215 167
Btu/h 25400 22200 18700 14900 11000
Watts 2790 2700 2610 2520 2390
Amps 11.6 11.9 12.4 12.9 13.3
Lb/h 305 282 250 209 161
Btu/h 28300 25200 21700 18000 14300
Watts 3110 3060 3020 2980 2910
Amps 14.6 14.9 15.3 15.7 16.1
Lb/h 340 320 291 255 214
Btu/h 32000 28800 25300 21600 17900 14400 11000
Watts 3370 3360 3380 3380 3360 3300 3180
Amps 17.0 17.2 17.6 18.1 18.4 18.4 18.1
Lb/h 385 366 340 307 270 230 190
Btu/h 36500 33100 29400 25600 21900 18300 14900
Watts 3580 3620 3680 3730 3770 3760 3690
Amps 19.0 19.2 19.6 20.0 20.3 20.4 20.0
Lb/h 442 422 396 365 331 295 260
Btu/h 41900 38100 34100 30100 26100 22400 18900 15900
Watts 3760 3840 3940 4050 4130 4170 4160 4070
Amps 20.5 20.7 21.1 21.6 21.9 22.0 21.7 20.9
Lb/h 511 489 462 430 397 363 331 302
Btu/h 48000 43800 39400 35000 30800 26700 23100 19900
25
30
35
40
45
50
55
Watts 3910 4040 4180 4330 4460 4550 4590 4560
Amps 21.7 22.0 22.4 22.9 23.3 23.5 23.3 22.5
Lb/h 592 567 537 504 469 436 405 379
Btu/h 55100 50300 45400 40500 35800 31400 27300 23900
Watts 4050 4210 4400 4590 4760 4910 5000 5020
Amps 22.6 23.0 23.5 24.1 24.6 24.9 24.7 24.0
Lb/h 688 657 622 586 549 514 483 458
Btu/h 63000 57500 51900 46500 41200 36300 31800 27900
Watts 4170 4380 4600 4840 5060 5250 5390 5460
Amps 23.4 23.9 24.5 25.2 25.8 26.2 26.1 25.6
Lb/h 799 760 719 677 637 599 566 539
Btu/h 71800 65500 59200 53000 47100 41500 36400 32000
Watts 4310 4540 4810 5080 5350 5580 5770 5900
Amps 24.1 24.6 25.4 26.3 27.0 27.5 27.6 27.2
Lb/h 924 877 828 779 733 690 653 624
Btu/h 81500 74300 67100 60100 53400 47100 41300 36200
Watts 4450 4720 5020 5340 5640 5920 6160 6330
Amps 24.7 25.4 26.4 27.4 28.3 29.0 29.3 29.0
Lb/h 1070 1010 950 893 839 789 747 714
Btu/h 92200 84000 75800 67800 60200 53000 46400 40500
Watts 4620 4920 5260 5610 5950 6280 6560 6780
Amps 25.4 26.3 27.4 28.6 29.7 30.6 31.1 31.1
Lb/h 1230 1160 1090 1020 955 897 848 809
Btu/h 94500 85200 76200 67500 59300 51700 44900
Watts 4810 5150 5520 5900 6290 6650 6980 7250
Amps 26.2 27.3 28.7 30.1 31.4 32.5 33.2 33.4
Lb/h 1400 1320 1240 1160 1080 1010 957 910
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 2.280943E+04 6.033304E+03 3.311841E+01 -9.703061E+01
C2 6.843429E+02 1.104403E+01 8.094909E-01 7.719106E+00
C3 4.949395E+02 -9.046107E+01 -7.124273E-01 1.371563E+01
C4 3.408910E+01 -1.038705E+00 -1.719899E-02 4.655325E-01
C5 -5.648465E+00 5.228528E-01 -2.165436E-03 -1.073698E-01
C6 -7.467700E+00 8.711571E-01 7.511487E-03 -1.331473E-01
C7 2.980219E-02 1.279852E-02 1.014127E-04 1.099556E-03
C8 -2.382623E-01 -3.139167E-03 5.574180E-05 -3.386581E-03
C9 4.358164E-02 2.515841E-03 3.473331E-06 1.064331E-03
C10 2.103242E-02 -3.085549E-03 -2.456880E-05 3.065791E-04
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature