Performance Data Sheet
AGA5553EXN
General Information
Model AGA5553EXN Refrigerant R-22
Test Condition ASHRAE Performance Test Voltage 230V ~ 60HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type PSC
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 16400 15600
Watts 2610 2420
Amps 12.5 11.6
Lb/h 225 203
Btu/h 18400 17100 15800
Watts 2790 2640 2480
Amps 13.4 12.7 11.9
Lb/h 249 226 203
Btu/h 21000 19300 17600 15900
Watts 2980 2850 2730 2610
Amps 14.3 13.7 13.1 12.5
Lb/h 281 256 231 206
Btu/h 24200 22100 20000 17900 15900
Watts 3160 3070 2980 2890 2800
Amps 15.2 14.7 14.3 13.9 13.5
Lb/h 320 293 266 240 213
Btu/h 28100 25600 23100 20600 18100
Watts 3340 3280 3230 3170 3120
Amps 16.0 15.7 15.4 15.2 14.9
Lb/h 367 338 309 281 252
Btu/h 32600 29700 26800 23900 21000 18200 15300
Watts 3510 3490 3470 3450 3430 3410 3390
Amps 16.7 16.6 16.5 16.4 16.4 16.3 16.2
Lb/h 420 390 359 329 299 269 239
Btu/h 37700 34400 31100 27800 24600 21300 18000
Watts 3670 3690 3700 3720 3740 3750 3770
Amps 17.4 17.5 17.6 17.7 17.8 17.8 17.9
Lb/h 480 448 416 385 353 321 290
Btu/h 43400 39700 36100 32400 28700 25100 21400
Watts 3830 3880 3930 3990 4040 4090 4140
Amps 18.1 18.4 18.6 18.9 19.1 19.4 19.6
Lb/h 546 513 480 447 414 381 348
Btu/h 49700 45700 41600 37600 33500 29400 25400
25
30
35
40
45
50
55
Watts 3980 4070 4160 4250 4330 4420 4510
Amps 18.7 19.1 19.6 20.0 20.4 20.8 21.3
Lb/h 619 585 551 516 482 447 413
Btu/h 56600 52200 47800 43300 38900 34500 30000
Watts 4110 4240 4370 4500 4620 4750 4870
Amps 19.2 19.8 20.5 21.1 21.7 22.3 22.9
Lb/h 699 663 628 592 556 520 484
Btu/h 64100 59300 54500 49700 44900 40100 35200
Watts 4240 4410 4580 4740 4910 5070 5230
Amps 19.7 20.5 21.3 22.1 22.9 23.6 24.4
Lb/h 784 748 711 674 637 600 563
Btu/h 72100 67000 61800 56700 51500 46300 41100
Watts 4360 4570 4770 4980 5180 5380 5580
Amps 20.0 21.0 22.0 23.0 24.0 25.0 25.9
Lb/h 875 838 801 763 725 687 648
Btu/h 80700 75200 69700 64200 58600 53100 47500
Watts 4460 4710 4960 5200 5440 5680 5920
Amps 20.3 21.5 22.7 23.9 25.0 26.2 27.3
Lb/h 972 934 896 857 818 779 740
Btu/h 89800 84000 78200 72300 66400 60500 54500
Watts 4550 4840 5130 5410 5690 5970 6250
Amps 20.5 21.9 23.3 24.7 26.0 27.4 28.7
Lb/h 1070 1040 997 958 918 878 837
Btu/h 99500 93300 87100 80900 74700 68400 62100
Watts 4630 4960 5290 5610 5930 6250 6570
Amps 20.6 22.2 23.8 25.3 26.9 28.5 30.0
Lb/h 1180 1140 1100 1060 1020 983 941
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 4.128800E+04 3.913225E+03 1.884154E+01 5.424033E+02
C2 1.332890E+03 -2.230552E+01 -1.139517E-01 1.079722E+01
C3 -2.153347E+02 -9.614926E+00 -4.711964E-02 -2.806191E+00
C4 1.163845E+01 -1.957201E-01 -1.429981E-03 1.245019E-01
C5 -7.476168E+00 7.553973E-01 3.678784E-03 -2.325463E-02
C6 9.437216E-03 9.846980E-04 5.762790E-06 1.642359E-04
C7 -1.271156E-02 -1.326350E-03 -7.762254E-06 -2.212193E-04
C8 1.257623E-02 1.312229E-03 7.679614E-06 2.188641E-04
C9 -3.561274E-03 -3.715905E-04 -2.174675E-06 -6.197687E-05
C10 1.705432E-04 1.779482E-05 1.041414E-07 2.967964E-06
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature