Tecumseh AEA3440AXA Performance Data Sheet

Performance Data Sheet
AEA3440AXA
General Information
Model AEA3440AXA Refrigerant R-12 Test Condition ASHRAE Performance Test Voltage 115V ~ 60HZ Return Gas 35°C (95°F) RETURN GAS Motor Type RSIR
Performance Information
20
25
30
35
40
45
50
55
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 3050 3050 2940 2750 2520 2290 2090 Watts 1120 702 503 456 488 529 506 Amps
Lb/h 53.1 50.2 47.6 45.3 43.1 41.1 39.0
Btu/h 3350 3360 3260 3070 2830 2590 2360 Watts 1220 767 543 479 502 542 526 Amps
Lb/h 58.8 55.9 53.3 51.0 48.8 46.6 44.4
Btu/h 3690 3710 3610 3420 3180 2910 2660 Watts 1320 834 587 507 523 562 554 Amps
Lb/h 64.9 62.0 59.4 57.0 54.8 52.6 50.3
Btu/h 4050 4090 3990 3800 3540 3260 2980 Watts 1420 900 631 537 546 587 588 Amps
Lb/h 71.4 68.5 65.9 63.5 61.2 58.9 56.5
Btu/h 4430 4480 4390 4190 3930 3620 3320 Watts 1510 963 673 565 569 613 625 Amps
Lb/h 78.1 75.2 72.7 70.3 67.9 65.6 63.1
Btu/h 4830 4890 4800 4600 4320 4000 3670 Watts 1590 1020 708 589 589 636 660 Amps
Lb/h 85.1 82.3 79.7 77.3 75.0 72.5 70.0
Btu/h 5240 5310 5220 5020 4720 4380 4020 Watts 1660 1060 735 605 602 655 692 Amps
Lb/h 92.3 89.6 87.0 84.6 82.2 79.7 77.1
Btu/h 5650 5730 5650 5430 5130 4760 4380 Watts 1720 1090 749 610 606 665 716 Amps
Lb/h 99.7 97.0 94.5 92.1 89.6 87.1 84.4
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 -4.304374E+03 1.848284E+04 0.000000E+00 8.797634E+01 C2 -6.306225E+01 1.294507E+02 0.000000E+00 5.089553E-01 C3 2.028141E+02 -4.785629E+02 0.000000E+00 -1.104890E+00 C4 1.324995E+00 1.274993E-01 0.000000E+00 1.137502E-02 C5 1.612998E+00 -2.112543E+00 0.000000E+00 4.170040E-03 C6 -1.974999E+00 4.172943E+00 0.000000E+00 6.874643E-03 C7 -7.500009E-03 -4.166882E-03 0.000000E+00 -5.833337E-05 C8 -1.499955E-03 2.550161E-03 0.000000E+00 9.999883E-06 C9 -7.500004E-03 7.899732E-03 0.000000E+00 -2.500013E-05
C10 5.833332E-03 -1.191649E-02 0.000000E+00 -1.666571E-05
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature
Loading...