AE3425Y­AA1AXA
Evaporator T, 80°F 90°F 100°F 110°F
°F PSIG BTUH Watts Cond T BTUH Watts Cond T BTUH Watts Cond T BTUH Watts Cond T
20 18.4 1620 260 109 1500 270 118 1380 270 126 1260 280 134 25 22.1 1800 270 112 1670 280 120 1540 290 129 1410 300 137 30 26.1 1990 290 115 1850 300 123 1710 310 131 1560 320 139 35 30.4 2190 310 118 2040 320 126 1880 330 134 1710 340 142 40 35.0 2400 330 122 2230 340 129 2050 350 137 --- --- --­45 40.0 2610 350 125 2420 360 133 2230 370 140 --- --- --­50 45.4 2830 370 129 2620 380 136 --- --- --- --- --- --­55 51.2 3040 390 133 2820 410 139 --- --- --- --- --- ---
Model
12.7 11.1 9.8 8.8 3/8” F 3/8” F N/A 240 9.5 32
* F = Flare, S = Solder, RF or RS = Rotolock with Flare or Solder Connections, C = Compression Fitting Factory charge: 20 PSIG Nitrogen – MUST BE EVACUATED
Ambient Temperatures
Dimensions, inches Line Connection* Pumpdown Air Oil Ch Gr. Wt.
L W H CH Suction Liquid
60 Hz Performance
Return gas temp. 65F, 5F sub cooling
90 F 90%
SCFM Oz. Lbs.
September 17, 2015
Revision: A
Specifications/ Parts:
Unit Model AE3425Y-AA1AXA Unit Bill of Material 2A524-1B
Refrigeration Range 20 F to 55° F Fan Blade 51567 Design Pressure Low 150 Fan Shroud 70735-1 Design Pressure High 450 Fan Guard N/A Nominal Volts-Hz-Ph 115/60/1 Condenser 50801-6 Voltage Range 103-127 Liquid Valve N/A Min. Circuit Ampacity 5.0 Suction Valve 56533-4 Max. Fuse Size (amps) 15 Power Cord 85106-10
Compressor Model AE3425Y-AA1A Unit Drawing DGU1896-237 Comp. Bill of Material AE1004E-212-J7 Wiring Diagram 91266-01 Compressor RLA/LRA 3.7/29 Overload 830-10043 Replacement Kit: Relay K71-34 Relay 820-10052 Replacement Kit: O/L K90-55 Run Capacitor N/A Replacement Kit: St. Cap N/A Start Capacitor N/A
Fan Motor 810M006C25
Fan Motor RLA 0.46
Electrical Diagram