Maintenance
Operation only allowed to qualied person, damages due to
unprofessional operation or remove of any parts inside will
not be considered in warranty service. There are no serviceable parts inside the device or package, service only leaves to
authorized dealers.
Never allow the optical components contact with oil, fat or
any other liquid.
A regular clearance of the device is needed for long-term usage, this is very helpful to maintain the lifetime and bright-
ness need to use a so and lint-free cloth to clean the optical
system, fan and air owing tunnel.
Trouble Shooting
Problems Possible reasons Checking or solutions
Device not power up
Powercon or power cable damaged Change a good power cable to try
Faulty power supply Replace new power supply
Pan/Tilt error or vibrate
Faulty Pan/Tilt PCB Replace PT001 PCB
Faulty opto sensor Replace opto sensor OP001
Cable loosen Check the cable connect to OP001
LED o
Temperature protection Check the temperature from menu
Fan not working Check the fan speed info from menu
Faulty LED Replace new LED
Dimmer and strobe set at 0 Set dimmer and strobe channel at 255
Faulty power supply Replace new power supply
Device not response to DMX
Faulty communication IC
Replace the IC with back-up one in the
display PCB
Faulty display PCB Replace new display PCB
Wrong DMX addressing Check the address and setting
Faulty DMX cable Change to a good DMX cable
Replacement of the fuse
Need to replace with same type and rating, which originally
installed in the device.
• Step One: Unplug power cable from main power.
• Step Two: Unscrew the fuse holder out of the housing
with a screwdriver.
• Step Three: Remove the broken fuse and replace with an
exact same type of new fuse.
• Step Four: Insert the fuse holder back to the housing and
screw tight and reconnect power.
p. 6ION 1915Z
ENGLISH VERSION