2.2.5. Trouble Shooting
2.2.6 Replacement of the fuse
Need to replace with same type and rating, which originally
installed in the device.
Step One: Unplug power cable from main power.
Step Two: Unscrew the fuse holder out of the housing with a
screwdriver.
Step Three: Remove the broken fuse and replace with an exact same type of new fuse.
Step Four: Insert the fuse holder back to the housing and
screw tight and reconnect power.
Problems Possible reasons Checking or solutions
Device not power up
Powercon or power cable damaged Change a good power cable to try
Faulty power supply Replace new power supply
Pan/Tilt error or vibrate
Faulty Pan/Tilt PCB Replace PT001 PCB
Faulty opto sensor Replace opto sensor OP001
Cable loosen Check the cable connect to OP001
LED o
Temperature protection Check the temperature from menu
Fan not working Check the fan speed info from menu
Faulty LED Replace new LED
Dimmer and strobe set at 0 Set dimmer and strobe channel at 255
Faulty power supply Replace new power supply
Device not response to DMX
Faulty communication IC Replace the IC with back-up one in the display PCB
Faulty display PCB Replace new display PCB
Wrong DMX addressing Check the address and setting
Faulty DMX cable Change to a good DMX cable
3. Installation
3.1 The device could be either put on a solid and even Sur-
face, or mounted upside down or sideways like le picture.
3.2 The mounting place must be suicient stable and be able
to support a weight of 10 times of the unit’s weight. When the
xture is hanged, always additionally secure the device with
the safety chain, fasten the safety rope at a suitable position
so that the maximum fall of the projector will be 20 cm
p. 8ION 575