Teco XPV0254C Data Sheet

NAMEPLATE INFORMATION
HP KW
25 18.7 60
TYPICAL PERFORMANCE
0
ALLOWABLE
PER HOUR
COLD
HOT
2
1
APPROVED:
REVISION
COLD
HOT
17
12
M. PRATER
DRAWING NO.
31057XPV0254C
SOUND
PRESSURE
LEVEL @ 3 FT
dB(A)
8.94
NEMA
LOAD
WK
2
Sec
MAX
ALLOWABLE
WK
2
Sec
SAFE STALL
TIME IN
SECONDS
74.37
200
135
220
NEMA
LOAD
WK
2
lb-ft
2
PULL
UP
%FLT
17.58
15.90
AT
460
VOLT
AT
208
VOLT
AT
208
VOLT
AT
230
VOLT
AT
230
VOLT
AT
460
VOLT
182.50
65.02
7.95
29.40
58.80
365.00
BREAK DOWN
%FLT
NEMA
KVA
CODE
LETTER
G
403.61
ACCEL TIME
INERTIA
4.425
ROTOR
WR
2
lb-ft
2
TORQUE
FULL LOAD
lb-ft
LOCKED
ROTOR
%FLT
220.00
1765
FULL
LOAD
RPM
POWER FACTOR
3/4 LOAD
%
1/2 LOAD
%
F. L.
%
85
93.6
94
FULL LOAD
MIN. %
NOM. %
3/4 LOAD
%
122
MAX
ALLOWABLE
WK
2
lb-ft
2
CURRENTS
NO LOAD
FULL LOAD
LOCKED ROTOR
5.04
AT
208
VOLT
AT
230
VOLT
AT
460
VOLT
TIME
RATING
CONT.
SERVICE
FACTOR
1.15
83
77
MAXIMUM
POWER FACTOR
CORRECTION
KVAR
6.3
INS.
CLASS
F
NEMA
DESIGN
B
VOLTAGE
230/460
HZ
RATED
AMBIENT
40oC
ISSUED
July 12, 2018
TYPE
AEUHXG
ENCLOSURE
EXPLOSION PROOF
CATALOG#
XPV0254C
PERFORMANCE DATA
3-PHASE INDUCTION MOTOR
68
OUTPUT
POLE
4
FRAME
SIZE
284TC
EFFICIENCY
1/2 LOAD
%
92.4
93.5