Teco XP1/58 Data Sheet

ACCEL TIME
INERTIA
TORQUE
POWER FACTOR
CURRENTS
ISSUED
EFFICIENCY
August 20, 2013
TYPE
AEHHXU
PERFORMANCE DATA
3-PHASE INDUCTION MOTOR
NAMEPLATE INFORMATION
OUTPUT
HP KW
1.5 1.12 60
POLE
8
FRAME
SIZE
184T
VOLTAGE
230/460
TYPICAL PERFORMANCE
FULL
LOAD
RPM
FULL LOAD
MIN. % NOM. %
75.5 70
78.5 75.5
3/4 LOAD
%
RATED
HZ
AMBIENT
1/2 LOAD
%
40oC
F. L.
%
60.5
INS.
CLASS
F
3/4 LOAD%1/2 LOAD
NEMA
DESIGN
B
51.5 39.5
ENCLOSURE
CATALOG#
TIME
RATING
CONT.
%
TEFC
XP1/58
SERVICE
FACTOR
1.15
MAXIMUM
POWER FACTOR
CORRECTION
KVAR2860
NO LOAD FULL LOAD LOCKED ROTOR
WK
Sec
6.83
AT
460
VOLT
20.006.54
ALLOWABLE
2
AT
208
VOLT
4.91 4.44
FULL LOAD
lb-ft
AT
230
VOLT
LOCKED
ROTOR
%FLT
AT
460
VOLT
2.22 2.965.91 40.00
PULL
UP
%FLT
AT
208
VOLT
BREAK
DOWN
%FLT
9.16 185 130 250
SAFE STALL
TIME IN
SECONDS
COLD HOT
78 55
APPROVED: REVISION
ALLOWABLE
STARTS
PER HOUR
2 1
M. PRATER
AT
230
VOLT
ROTOR
2
WR
2
lb-ft
0.275
SOUND
PRESSURE
LEVEL @ 3 FT
dB(A)
VOLT
NEMA
LOAD
45.2751
53
DRAWING NO.
AT
460
WK lb-ft
2
2
AT
208
VOLT
MAX
ALLOWABLE
WK lb-ft
AT
230
VOLT
NEMA
2
2
LOAD
223
31057XP1/58
NEMA
KVA
CODE
LETTER
MAX
WK
Sec
33.48
M44.23
2
0