Teco XP1/56C Data Sheet

ISSUED
April 11, 2011
TYPE
AEHHXF
PERFORMANCE DATA
3-PHASE INDUCTION MOTOR
NAMEPLATE INFORMATION
OUTPUT
HP KW
1.5 1.1 60
POLE
6
FRAME
SIZE
182TC
VOLTAGE
230/460
TYPICAL PERFORMANCE
FULL
LOAD
RPM
FULL LOAD
MIN. % NOM. %
85.5 83.5
EFFICIENCY
3/4 LOAD
%
87.5 87
RATED
HZ
AMBIENT
40oC
1/2 LOAD
%
INS.
CLASS
F
POWER FACTOR
F. L.
%
3/4 LOAD%1/2 LOAD
63
NEMA
DESIGN
B
%
54 42
ENCLOSURE
EXPLOSION PROOF
CATALOG#
XP1/56C
TIME
RATING
CONT.
POWER FACTOR
SERVICE
FACTOR
1.15
MAXIMUM
CORRECTION
KVAR1.41170
NO LOAD FULL LOAD LOCKED ROTOR
AT
208
VOLT
3.78 3.42
FULL LOAD
lb-ft
AT
230
VOLT
TORQUE
LOCKED
ROTOR
%FLT
AT
460
VOLT
1.71 2.555.10 40.00
PULL
UP
%FLT
6.731 230 225 370
SAFE STALL
TIME IN
SECONDS
COLD HOT
97 68
ALLOWABLE
STARTS
PER HOUR
2 1
AT
208
VOLT
BREAK
DOWN
%FLT
CURRENTS
AT
230
VOLT
ROTOR
2
WR
2
lb-ft
0.313
SOUND
PRESSURE
LEVEL @ 3 FT
dB(A)
55
AT
460
VOLT
NEMA
LOAD
WK lb-ft
23
2
2
AT
208
VOLT
MAX
ALLOWABLE
WK lb-ft
2
2
163.00
AT
230
VOLT
ACCEL TIMEINERTIA
NEMA
LOAD
WK
Sec
4.73
AT
460
VOLT
20.005.64
ALLOWABLE
2
NEMA
KVA
CODE
LETTER
MAX
2
WK
Sec
33.11
M44.23
APPROVED: REVISION
M. PRATER
DRAWING NO.
31057XP1/56C
0
Loading...