Teco XP0304C Data Sheet

ISSUED
May 14, 2011
TYPE
AEHHXF
PERFORMANCE DATA
3-PHASE INDUCTION MOTOR
NAMEPLATE INFORMATION
OUTPUT
HP KW
30 22.4 60
POLE
4
FRAME
SIZE
286TC
VOLTAGE
230/460
TYPICAL PERFORMANCE
FULL
LOAD
RPM
FULL LOAD
MIN. % NOM. %
92.4 93.5
EFFICIENCY
3/4 LOAD
%
93.6 94
RATED
HZ
AMBIENT
40oC
1/2 LOAD
%
INS.
CLASS
F
POWER FACTOR
F. L.
%
85.5
3/4 LOAD%1/2 LOAD
83.5 76.5
NEMA
DESIGN
B
ENCLOSURE
EXPLOSION PROOF
CATALOG#
XP0304C
TIME
RATING
CONT.
POWER FACTOR
%
SERVICE
FACTOR
1.15
MAXIMUM
CORRECTION
KVAR7.81765
NO LOAD FULL LOAD LOCKED ROTOR
AT
208
VOLT
21.67 19.60
FULL LOAD
lb-ft
AT
230
VOLT
TORQUE
LOCKED
ROTOR
%FLT
AT
460
VOLT
9.80 35.1070.20 435.00
PULL
UP
%FLT
89.24 190 145 230
SAFE STALL
TIME IN
SECONDS
COLD HOT
17 12
ALLOWABLE
STARTS
PER HOUR
2 1
AT
208
VOLT
BREAK
DOWN
%FLT
CURRENTS
AT
230
VOLT
ROTOR
2
WR
2
lb-ft
5.044
SOUND
PRESSURE
LEVEL @ 3 FT
dB(A)
70
AT
460
VOLT
NEMA
LOAD
WK lb-ft
144
2
2
AT
208
VOLT
MAX
ALLOWABLE
WK lb-ft
2
2
237.00
AT
230
VOLT
ACCEL TIMEINERTIA
NEMA
LOAD
WK
Sec
4.91
AT
460
VOLT
217.5077.63
ALLOWABLE
2
NEMA
KVA
CODE
LETTER
G481.01
MAX
2
WK
Sec
7.97
APPROVED: REVISION
M. PRATER
DRAWING NO.
31057XP0304C
0
Loading...