Teco VSKTP4006 Data Sheet

ISSUED
August 25, 2017
TYPE
AEHCEC
PERFORMANCE DATA
3-PHASE INDUCTION MOTOR
NAMEPLATE INFORMATION
OUTPUT
HP KW
400 298 60
POLE
6
FRAME
SIZE
5808
VOLTAGE
2300/4000
TYPICAL PERFORMANCE
FULL
LOAD
RPM
1190
FULL LOAD 3/4 LOAD
MIN. % NOM. %
94.5
EFFICIENCY
%
95.4 95.2 94.6
RATED
HZ
AMBIENT
40oC
%
INS.
CLASS
F
POWER FACTOR
F. L.
%
3/4 LOAD%1/2 LOAD
80.7
75.8
NEMA
DESIGN
B
ENCLOSURE
CATALOG#
TIME
RATING
CONT.
%
65.0
TEFC
VSKTP4006
SERVICE
FACTOR
1.15
MAXIMUM
POWER FACTOR
CORRECTION
KVAR136
CURRENTS
NO LOAD FULL LOAD LOCKED ROTOR
AT
2300
VOLT
FULL LOAD
lb-ft
AT
4000
VOLT
TORQUE
LOCKED
ROTOR
%FLT
1760 90 80
SAFE STALL
TIME IN
SECONDS
COLD HOT
17 14
AT
2300
VOLT
98.0
PULL
UP
%FLT
AT
4000
VOLT
56.3 364 G
BREAK
DOWN
%FLT
200
ALLOWABLE
STARTS
PER HOUR
COLD HOT
2 1
AT
2300
VOLT
63334.1 19.6
ROTOR
WR lb-ft
327
SOUND
PRESSURE
LEVEL @ 3 FT
dB(A)
2 2
83
AT
4000
VOLT
INERTIA
NEMA
LOAD
2
WK
2
lb-ft
4199
NEMA
KVA
CODE
LETTER
MAX
ALLOWABLE
WK
lb-ft
2 2
7558
ACCEL TIME
NEMA
LOAD
WK
Sec
2
MAX
ALLOWABLE
WK
Sec
6.77 11.80
2
APPROVED:
M. PRATER
DRAWING NO.
31059VSKTP4006
REV.
0
Loading...