Teco VHTP1256 Data Sheet

ISSUED
10/31/18
TYPE
AEEHNH
PERFORMANCE DATA
3-PHASE INDUCTION MOTOR
NAMEPLATE INFORMATION
OUTPUT
HP KW
125 93 60
POLE
6
FRAME
SIZE
445
VOLTAGE
460
TYPICAL PERFORMANCE
FULL
LOAD
RPM
FULL LOAD
MIN. % NOM. %
EFFICIENCY
3/4 LOAD
%
1/2 LOAD
94.1
HZ
RATED
AMBIENT
40oC
%
INS.
CLASS
F
POWER FACTOR
F. L.
%
3/4 LOAD%1/2 LOAD
79.095.0 94.9 94.5
ENCLOSURE
CATALOG#
NEMA
DESIGN
B
%
74.0 64.0
TEFC
VHTP1256
TIME
RATING
CONT.
POWER FACTOR
CORRECTION
SERVICE
FACTOR
1.15
MAXIMUM
KVAR431186
CURRENTS
NO LOAD
53.6 155
TORQUE
FULL LOAD
lb-ft
LOCKED
ROTOR
%FLT
553.7 100 100
SAFE STALL
TIME IN
SECONDS
COLD HOT
22 17
APPROVED:
M. PRATER
PULL
UP
%FLT
ALLOWABLE
STARTS
PER HOUR
COLD
LOCKED ROTOR
988
BREAK
DOWN
%FLT
ROTOR
WR lb-ft
66.9
SOUND
PRESSURE
LEVEL @ 3 FT
HOT
1
DRAWING NO.
CODE LETTER
2 2
dB(A)
792
NEMA KVA
G
INERTIA
NEMA
LOAD
2
WK
2
lb-ft
1452
31057VHTP1256
MAX
ALLOWABLE
WK
lb-ft
2 2
1888
ACCEL TIME
NEMA
LOAD
WK
Sec
2
MAX
ALLOWABLE
WK
Sec
6.60220 8.50
REVISION
2
0