Teco VHTP0154 Data Sheet

ISSUED
January 17, 2017
TYPE
AEEHNH
PERFORMANCE DATA
3-PHASE INDUCTION MOTOR
NAMEPLATE INFORMATION
OUTPUT
HP KW
15 11.2 60
POLE VOLTAGE
4
FRAME
SIZE
254TP
230/460
TYPICAL PERFORMANCE
FULL
LOAD
RPM
FULL LOAD
MIN. % NOM. %
91.0 92.4
EFFICIENCY
3/4 LOAD
%
92.4 93.0
HZ
1/2 LOAD
RATED
AMBIENT
%
INS.
CLASS
40oC
F. L.
%
F
POWER FACTOR
3/4 LOAD%1/2 LOAD
88.0 85.0 77.0
NEMA
DESIGN
B
ENCLOSURE
CATALOG#
TIME
RATING
CONT.
%
TEFC
VHTP0154
SERVICE
FACTOR
1.15
MAXIMUM
POWER FACTOR
CORRECTION
KVAR4.81765
CURRENTS
NO LOAD FULL LOAD LOCKED ROTOR
AT
208
VOLT
14.77 17.2734.55 232.00
FULL LOAD
lb-ft
AT
230
VOLT
12.08
LOCKED
ROTOR
%FLT
AT
460
VOLT
PULL
UP
%FLT
AT
208
VOLT
BREAK
DOWN
%FLT
45 245 180 270
SAFE STALL
TIME IN
SECONDS
COLD HOT
32 22
ALLOWABLE
STARTS
PER HOUR
2 1
AT
230
VOLT
ROTOR
2
WR
2
lb-ft
2.179
AT
460
VOLT
NEMA
LOAD
WK lb-ft
75
2 2
AT
208
VOLT
MAX
ALLOWABLE
WK
lb-ft
2 2
220
AT
230
VOLT
NEMA
LOAD
WK
Sec
4.27
VOLT
116.0038.206.04
ACCEL TIMEINERTIATORQUE
2
AT
460
NEMA
KVA
CODE
LETTER
G256.54
MAX
ALLOWABLE
WK
Sec
2
12.23
APPROVED: REVISION
M. PRATER
DRAWING NO.
31057VHTP0154
0