Teco MP1252 Data Sheet

ISSUED
October 10, 2019
TYPE
AESV3W
PERFORMANCE DATA
3-PHASE INDUCTION MOTOR
NAMEPLATE INFORMATION
OUTPUT
HP KW
125 93.3 60
POLE
2
FRAME
SIZE
VOLTAGE
280M 230/460
TYPICAL PERFORMANCE
FULL
LOAD
RPM
3570
FULL LOAD
MIN. %
94.3 94.0
EFFICIENCY
NOM. %
3/4 LOAD
%
1/2 LOAD
95.0 94.7 89.5
HZ
RATED
AMBIENT
40oC
%
INS.
CLASS
F
POWER FACTOR
F. L.
%
3/4 LOAD%1/2 LOAD
86.5
NEMA
DESIGN
B
ENCLOSURE
CATALOG#
TIME
RATING
CONT.
%
80.0
TEFC
MP1252
SERVICE
FACTOR
1.15
MAXIMUM
POWER FACTOR
CORRECTION
KVAR28.2
NO LOAD FULL LOAD
AT
230
VOLT
70.9
FULL LOAD
lb-ft
LOCKED
ROTOR
%FLT
AT
460
VOLT
35.5
PULL
UP
%FLT
249.5 200 170 280
SAFE STALL
TIME IN
SECONDS
COLD HOT
9 6
ALLOWABLE
STARTS
PER HOUR
COLD HOT
2 1
AT
230
VOLT
BREAK
DOWN
%FLT
CURRENTS
ROTOR
2
WR
2
lb-ft
SOUND
PRESSURE
LEVEL @ 3 FT
dB(A)
83
AT
460
VOLT
NEMA
LOAD
WK lb-ft
113.0
LOCKED ROTOR
AT
230
VOLT
2390
MAX
2 2
ALLOWABLE
WK
lb-ft
2 2
460
VOLT
1195
NEMA
LOAD
WK
Sec
2.42.400
AT
ACCEL TIMEINERTIATORQUE
2
NEMA
KVA
CODE
LETTER
J
MAX
ALLOWABLE
WK
Sec
2
2.4
APPROVED:
K. Lo
DRAWING NO.
31057MP1252
REVISION
0